At a 0° position, the spring
bolt should already click into
place on the ground.
When the ground is uneven,
the spring bolts may not
correctly click into place.
To ensure that it has
correctly locked into place
while the speakers are on
the ground, you may need
to manually assist, especially
with a 0 degree angle.
3.
During lifting, the
connectors should slide
along the spring bolts – one
after the other from top to
bottom – until the bolts snap
into place and secure the
connection.
Warning
If the spring bolts do not
snap into place properly,
the array may not be
lifted any further.
If the spring bolts have
not snapped into place,
lower the array and
correct the error.
4.
Caution
Make sure that the spring
bolts have completely
locked into place.
The bolts are in the
correct position when
they slightly protrude out
of the connecting plate
on the opposite side.
5.
When the first speakers are
at working height, you can
remove the castor bases of
the SEQUENZA 5 B speakers
and mount the optional rain
protections for this speaker
model if necessary.