7.2
With rotated Horn
rotated horn
standing speakers
Winkel 2
Winkel 3
Winkel 1
A smaller angle
3 results in a
smaller vertical
coverage angle
but increases the
sound power
level.
Combination
Angle 1
Angle 2
Angle 3
Gravis 15 N with
Gravis 15 N
30°
Gravis 15 N with
Gravis 15 W
35°
Gravis 15 N with
Gravis 15 XW
40°
Gravis 15 W with
Gravis 15 W
45°
Gravis 15 W with
Gravis 15 XW
50°
Gravis 15 XW with
Gravis 15 XW
20°
30°
55°
Application
Increasing the
horizontal
coverage angle,
e.g. for wide
audience areas
Increasing the
horizontal
coverage angle
and sound
pressure level for
larger distances
Increasing the
vertical angle,
e.g. for covering
balconies
8.
Wiring Instructions
•
Before connecting your GRAVIS 15 loudspeaker switch off all equipment and turn down
all level controls.
•
Only use high-quality speaker cables with a sufficient wire gauge. The wire gauge
depends on the length of the speaker cable.
Minimum Wire Gauge (mm²)
= Required Cable Length (m) / (2 x Speaker Impedance (Ohm))
•
For connections to the power amplifier inputs, please use 2-pin shielded microphone
cable (balanced) with high-quality connectors.