3.

Safety Instructions

3.1

Mounting the Speakers / Wall and Ceiling Installation

Warning

Suspended loads pose a safety risk.

Only qualified technicians are permitted to perform the installation steps. Be sure to use
personal protective equipment at all times.

The technicians installing the speaker on site are responsible for and guarantee safe setup
and use.

Never use signal cables or power cords for suspending, aligning, or securing the systems.

Before installing, check the stability, strength, and materials of walls, ceilings, and boarding.
For example, use suitable rawlplugs for wall panels and make sure the strength is sufficient.

Note that the suspension points on the hall ceiling (i.e. shackles, attachment points, or chain
hoists) must comply with the DGUV regulations 17 or similar locally applicable accident-
control standards. The maximum load must have been certified by an authorized expert.

Be sure to tighten all bolts and screws to the specified torque.

Unless otherwise stated, use only KLING & FREITAG original parts for mounting the speakers.
Never use other parts (in particular, parts not made by KLING & FREITAG).

Make sure all fittings used are suitable for the task at hand and meet all relevant safety
requirements.

Ensure that all connections are secured against coming loose and that only authorized,
statically tested and correctly sized supports, mounting equipment, wire ropes and chains are
used.

Be sure to always visually inspect all safety-related speaker and accessory components
before use. If there are signs of wear, cracks, or deformation, etc., replace the affected parts
immediately. Visual inspection also includes checking all screwed connections of supporting
components.

The information described here does not relieve the user of the duty to follow the given
safety requirements and legal regulations.

3.2

Notes for Mounting the Speakers

Warning

Mount the speakers securely. To avoid injury or damage, always be sure to mount the
speakers securely so that they do not fall.

Please note that speakers can move as a result of vibrations. To prevent them from falling
from their mounted position, they must be secured properly.

Run the cables in a way that nobody can trip over them.

3.3

Preventing Hearing Damage

Caution

Keep your distance from operating speakers. This equipment is capable of delivering sound
pressure levels in excess of 90 dB SPL, which may cause permanent hearing damage.

3.4

Protecting the Speakers / Operating Safety

GRAVIS 15 speakers may only be used in combination with a K&F SystemAmp/SystemRack.

Содержание GRAVIS 15

Страница 1: ...Please Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Operating Instructions Translation of the original instruct...

Страница 2: ......

Страница 3: ...spending the Speakers 12 5 Rotating the high frequency horn 13 6 Configuration and Connecting Diagram 14 6 1 Controller Mode Full Range 14 6 2 Operations with an additional Subwoofer 14 7 Arrayed Spea...

Страница 4: ...5 KLING FREITAG GMBH 2016 Version 2 7 Page 4 of 32 13 6 Coverage GRAVIS 15 XW 27 14 Dimensions 28 15 Disposal 29 15 1 Germany 29 15 2 EU Norway Iceland and Liechtenstein 29 15 3 All Other Countries 29...

Страница 5: ...age Tip This icon marks information provided for simplified use of the described products 1 2 About these operating instructions KLING FREITAG GMBH All rights reserved All specifications regarding the...

Страница 6: ...ting K F Lifting Pin The model GRAVIS 15 N is equipped with a rotatable tweeter horn with a coverage angle of 65 x 50 The model GRAVIS 15 W has a coverage angle of 90 x 50 Its elegant design suitable...

Страница 7: ...threads 2 Speaker handle with drill hole prevents liquids from building up in the handle area 3 2x handle 4 speaker enclosure 5 2x SpeakOn connector 4 pin NLT4MP parallel 6 13x Plastic gliding foot 5...

Страница 8: ...K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 8 of 32 2 4 Accessories Adjustable Speaker Mount GRAVIS 15 Ceiling Bracket GRAVIS 15 Adjustable Wall Mount 50 Lifting Pin M10 x 17 Eyebolt Prote...

Страница 9: ...KLING FREITAG GMBH 2016 Version 2 7 Page 9 of 32 Stand socket M10 Pipe Clamp for TV Spigot TV Spigot 20 mm Spigot 20 mm 2 5 Required Tools To rotate the high frequency horn 3 mm Allan key for looseni...

Страница 10: ...sure all fittings used are suitable for the task at hand and meet all relevant safety requirements Ensure that all connections are secured against coming loose and that only authorized statically test...

Страница 11: ...he following signals may damage the speakers permanent high level signals with high frequency and continuous noise from feedback permanently distorted high level signals noises which occur when the am...

Страница 12: ...r for fixing it on a wall or ceiling we recommend you to use the accessories Adjustable Speaker Mount GRAVIS 15 U Mount Wall Ceiling Bracket GRAVIS 15 or Adjustable Wall Mount 50 By using these access...

Страница 13: ...When you use it as a stage monitor you have a good coverage into the depth of the stage and an optimal lateral sound field boundary on the stage For special uses the horn can also be rotated If you wi...

Страница 14: ...uster for the top speakers via Filter B if you wish to operate several tops next to one another If you need a higher bass level activate the filter BassBoost via Filter B for the top speakers BassBoos...

Страница 15: ...ter for the top speakers via Filter B if you wish to operate several tops next to one another If you need a boost in the low frequency range please activate the filfer LoMidBoost via Filter B If neces...

Страница 16: ...t rotated horn standing speakers Winkel 2 W i n k e l 3 Winkel 1 A smaller angle 3 results in a smaller vertical coverage angle but increases the sound power level Combination Angle 1 Angle 2 Angle 3...

Страница 17: ...is 15 XW 20 30 55 Application Increasing the horizontal coverage angle e g for wide audience areas Increasing the horizontal coverage angle and sound pressure level for larger distances Increasing the...

Страница 18: ...ons Successively turn up the individual power amplifier channels and send a signal with low volume to the system Check whether the audio is properly routed to the appropriate speakers Make sure no noi...

Страница 19: ...hould arise with regard to safety or defects are found don t use the speaker any longer Inspection regulations may vary depending on application and country of use Observe all applicable regulations w...

Страница 20: ...range 3 dB 100 Hz 20 kHz LCut Mode 64 Hz 20 kHz FR Mode 60 Hz 20 kHz BassBoost Mode Coverage angle nominal 90 x 50 hor x vert Power handling 500 W normal LCut mode 1000 watts program 1 2000 watts peak...

Страница 21: ...z BassBoost Mode Coverage angle nominal 65 x 50 hor x vert Power handling 500 watts nominal IEC 268 5 1000 watts program 1 2000 watts peak Max SPL 1 m 136 dB Components 15 bass midrange loudspeaker 1...

Страница 22: ...20 kHz LCut Mode 64 Hz 20 kHz FR Mode 60 Hz 20 kHz BassBoost Mode Coverage angle nominal 110 x 50 hor x vert Power handling 500 watts nominal IEC 268 5 1000 watts program 1 2000 watts peak Max SPL 1 m...

Страница 23: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 23 of 32 13 Measuring Diagrams 13 1 Frequency range GRAVIS 15 N 13 2 Frequency range GRAVIS 15 W...

Страница 24: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 24 of 32 13 3 Frequency range GRAVIS 15 XW LCut mode FR mode BassBoost mode LCut mode FR mode BassBoost mode...

Страница 25: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 25 of 32 13 4 Coverage GRAVIS 15 N Horizontal Vertical...

Страница 26: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 26 of 32 13 5 Coverage GRAVIS 15 W Horizontal Vertical...

Страница 27: ...2016 Version 2 7 Page 27 of 32 13 6 Coverage GRAVIS 15 XW Horizontal Attenuation dB 3 6 6 9 9 12 12 15 15 18 18 3 180 150 120 90 60 30 0 30 60 90 120 150 180 Vertical Attenuation dB 3 6 6 9 9 12 12 15...

Страница 28: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 28 of 32 14 Dimensions Weight 25 9 kg...

Страница 29: ...subject to the WEEE that are distributed in Germany with an icon showing a crossed out garbage can with a white bar below it The icon indicates that the equipment was distributed on or after 24 March...

Страница 30: ...ions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 30 of 32 15 3 All Other Countries Contact your retailer or the local authorities for information on the regulations applicable in any countr...

Страница 31: ...SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage used...

Страница 32: ...Operating Instructions K F GRAVIS 15 KLING FREITAG GMBH 2016 Version 2 7 Page 32 of 32 Managing Director CEO...

Отзывы: