9.1.2
Full-Range Mode with Subwoofer
You can link the input signal (for example from the mixer) from one loudspeaker to
another. It makes no difference whether the input signal reaches the bass speaker first
and is then transmitted to the mid-high speaker or the other way around.
The switch ‘FILTERS’ on
the SP speaker must be
at ‘ON’ in this mode.
If you are operating a mid-range system in a cluster (speakers arranged in close prox-
imity) reduce the frequencies below 300 Hz by 3-4 dB! (The K&F C2 Controller has for
this purpose a 'Top-Low Cut' switch.)
INPUT
Channel 2
Channel 1
LINE
AC-MAINS
LINE
AC-MAINS
AC ~ 16 A max.
To next
'SP'-Top
or Bass
LINE
AC-MAINS
LINE
AC-MAINS
AC ~ 16 A max.
To next
'SP'-Top
or Bass