8.2
Connecting the Power Connectors to the Connecting Terminal
2.
1.
3.
1.
2.
Only use the supplied power cable and connect it to a mains outlet with a 16 A fuse.
See instructions in chapter 4 ‘Power Cord’ on page 13.
9.
Configurations and Connecting Diagrams
9.1
Operating the Systems without C2 Controller
The full-range system can be used alone or in conjunction with an SP subwoofer. The
subwoofer has an integrated filter for use in this mode, which limits the bandwidth.
The full-range system is protected against low frequency (subsonic) signals by a high-
pass filter and when used with bass speakers it is phase aligned with the subwoofers by
means of alignment filters.
9.1.1
Full-Range Mode
This mode of operation is ideal for speech and music applications without the need for
a high bass content. Should more bass be needed, the bass level can be increased be-
tween 50 and 80 Hz at the mixing console.
The switch ‘FILTERS’ on
the SP speaker must be
at ‘ON’ in this mode.
If you are operating a mid-range system in a cluster (speakers arranged in close prox-
imity) reduce the frequencies below 300 Hz by 3-4 dB! (The K&F C2 Controller has for
this purpose a ‘top low cut’ switch.)
INPUT
Channel 2
Channel 1
LINE
AC-MAINS
LINE
AC-MAINS
AC ~ 16 A max.
AC ~ 16 A max.
Warning