background image

                                   10 

                                                  

explosion-proof duct fan

  WP-11/Ex                        

 

       04.06.2019 

   

 

 

10.

 

Occupational Health and Safety 

Start-up and the operational use of the fan are admissible

  

after getting acquainted with   

the contents of the present Use and Maintenance Manual

The

 fan shall not cause any ha-

zard under the condition

 it 

is correctly

 and 

firmly installed within the ventilation system or other 

structural element of the building. 
Any installation activities related to 

the

 power supply system, have to be carried out strictly ac- 

cording to the enclosed 

Connection Diagram

  and  in accordance

  

with the instructions given in 

Section 6 of the present Use and Maintenance Manual. 

 

 

Connection to the

 power supply system ought

 to be 

carried out

 by an au

thorised person with

 qualifications, according to the being in force regulations. 

The fan motor ought to be protected against the short-circuit- and overload effects. During the  
use, check the fan connection to the PE protective cable. 

In the course of operational use, examine 

the

 fan connection to the PE protective cable

.

 

 

Any revision activity and repair must be executed after the fan is disconnec-
ted from the power supply system.   
Approaching with 

“loose garment/clothing” or putting the hand towards the 

open inlet

 of the 

running fan can cause hazard

 of 

accident 

and

 severe 

disabi

lity.

 

 

 

11.

 

Transport and Storage 

WP-11/Ex ought to be wrapped in foil and placed into the cardboard package. Put the weight 
description on the package.  During loading re-loading and transporting, the fans should not  
be thrown neither knocked down. Do not put any additional load on its top. 
It is inadmissible to put one device on top of another (no stacking). During the transport, pro- 
tect the device from atmospheric factors (weather conditions) and from mechanical damage. 
The device should be stored in dry rooms and in areas of efficient ventilation. 
 

12.

 

Terms of warranty 

The period of warranty for the purchased device 

is

 indicated in the

 

Card 

of Warranty”. The war-

ranty does not comprise:

 

●  mechanical damages and malfunctions caused by User, 
●  device failures caused during use which was in contradiction with the purpose

 of application

 

and with the present Use and Maintenance Manual, 

● 

any damages being caused during

 

improper

 transport, storage

 or 

incorrect maintenance. 

Infringement of the Clause G

 

Section 3 “Reservations of Producer” of the present Use and 

Maintenance Manual

 and

 

especially modifications undertaken by User on one’s own or use 

in contradiction

 with the

 purpose

 of 

application

  

  

shall result in the loss of warranty validity. 

 

 

Содержание WP-11/Ex

Страница 1: ...2 Application 3 3 Reservations of Producer 3 4 Technical Data 4 5 Structure and Function 5 6 Assembly and Start up 5 7 Operational Use 8 8 Troubleshooting Guide 9 9 Maintenance 9 10 Occupational Healt...

Страница 2: ...of February 26th 2014 on the harmonisation of the laws of Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres Journal of Laws EC L96 of 29...

Страница 3: ...factories in areas of explosion hazard but this cannot be methane firedamp hazard neither carbon dust occurrence category 2 the device is designed for application in areas where explosive atmosphe re...

Страница 4: ...eed the nominal rotations I Manufacturer is not responsible for wounds injuries body laceration experienced by User or personnel during the improper operational use 4 Technical Data Table No 1 Type Ro...

Страница 5: ...ckage check the state of the fan if there are no damages that occurred during the transport WP 11 Ex duct fans are installed inside the rooms indoor application in vertical and horizontal round rigid...

Страница 6: ...lations of Occupational and Health Safety and with the instructions given in Fig No4 CAUTION The fan is equipped with protective cables that should be connected to the ventila tion ducts Additionally...

Страница 7: ...nnection and the target connection of the motor windings should be performed by investor too S1 isolating switch in Ex execution It is suggested to install the isolating switch in a place near the fan...

Страница 8: ...tor Following use of the fan is treated as incorrect a conveying the aggressive media b forwarding the media of high dustiness or contaminant particles content c use of the fan in area where the ambie...

Страница 9: ...it the fan to technical revision in regular periods of time Technical revisions on the fan must be executed by a qualified person with adequate authorization Additionally the fan necessarily should by...

Страница 10: ...se garment clothing or putting the hand towards the open inlet of the running fan can cause hazard of accident and severe disabi lity 11 Transport and Storage WP 11 Ex ought to be wrapped in foil and...

Страница 11: ...Electrical equipment of machines Part 1 Gene ral requirements EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from be ing reached by upper and lower limbs EN 80079 0 2013...

Страница 12: ...12 explosion proof duct fan WP 11 Ex 04 06 2019 NOTES...