Ex-proof roof fans

  WP-

-D/Ex 

 

 

 
 

3.

 

Reservations of Producer 

 

A. 

Manufacturer accepts no liability for any consequences following from the operational use 
that is in contradiction to the purpose of application. 

 

 

B. 

Installing any additional elements not belonging to the normal device structure  
(or accessory set) is not acceptable. 

 

 

C. 

Any structural changes or device 

modifications on one’s own are not permitted. 

 

 

D. 

Protect the appliance’s housing from mechanical damage. 

 

 

E. 

Before installing 

– it is important it examine the load carrying capability of the structural 

elements of the building where the roof fan shall be installed. Unsure mounting could re- 
sult in uncontrolled device detachment, its damage and hazard to people in the vicinity. 

 

 

F. 

 

Do not use the fan for conveying the air containing viscous impurities  
that could deposit on the device surface, especially on the impeller. 

 

 

 

G. 

 

Neither use it for forwarding the air with aggressive pollutants which 
will destructively effect the device structure. 

 

 

H. 

During operation, the maximum impeller rotations should not exceed the nominal rotations. 

 

 

I. 

Producer is not responsible for wounds, injuries, body laceration experienced by 
User or personnel during the improper operational use. 

 
 

4.

 

Technical Data 

Table No.1 

Type 

Synchro- 

nous 

rotations 

 

 

 

[1/min] 

Supply 

voltage 

 

 

 

 

[V] 

Motor 

rate 

 

 

 

 

[kW] 

Ingress 

protect-

tion 

 

IP 

Acoustic 

pressure 

level 

[dB(A)] 

from the  

INLET   

from distance 

Acoustic 

pressure 

level 

[dB(A)] 

from the 

OUTLET   

from distance 

Maximum 

volume flow 

 

 

 

 

[m

3

/h] 

Maximum 

vacuum 

 

 

 

 

[Pa] 

Weight 

 

 

 

 

 

[kg] 

1m 

5m 

1m 

5m 

WP-3-D/Ex 

3000 

3 x 400 

0,37 

54 

58 

51 

61 

52 

900 

900 

19 

WP-5-D/Ex 

3000 

3 x 400 

0,55 

54 

63 

55 

64 

56 

1550 

1400 

24 

WP-7-D/Ex 

3000 

3 x 400 

1,1 

54 

67 

61 

71 

62 

2200 

1850 

26 

WP-8-D/Ex 

3000 

3 x 400 

1,5 

54 

72 

64 

77 

67 

2500 

2200 

37 

WP-9-D/Ex 

3000 

3 x 400 

2,2 

54 

74 

67 

77 

68 

2800 

2500 

43 

WP-10-D/Ex 

3000 

3 x 400 

4,0 

54 

75 

68 

78 

69 

4250 

2400 

78 

WP-11-D/Ex 

3000 

3 x 400 

4,0 

54 

77 

69 

80 

70 

5000 

2700 

80 

 

Noise measurement has been conducted: 

 

– 

at maximum volume flow, 

 

 at the 

TK 

silencer attached at the fan inlet (silencer length 

370

 

mm

 for 

WP-3-E/Ex

 

   and 1000 mmm for the other fans from the series, 

1. 

Maximum temperature of the conveyed air is +

60ºC,  

whereas maximum temperature within the work zone +4

0ºC. 

2. 

Maximum dustiness of the conveyed air should not exceed 0,3 g/m

3

 
 

 

Содержание WP-10-D/Ex

Страница 1: ...1 18 10 2016 Ex proof roof fans WP D Ex Use and Maintenance Manual Explosion proof roof fans WP D Ex ATEX mark II 2 G c Ex e ll T3...

Страница 2: ...servations of Producer 5 4 Technical Data 5 5 Structure and Function 7 6 Assembly and Start up 7 7 Operational Use 9 8 Troubleshooting Guide 9 9 Maintenance 10 10 Occupational Health and Safety 10 11...

Страница 3: ...vailable on the market of electrical equipment designed within certain voltage limits Journal of Laws EC L96 of 29 03 2014 2014 34 EC ATEX Directive of the European Parliament and of the Council of Fe...

Страница 4: ...pheres are possible to occur It can be applied in zones 1 2 G the appliance is marked on the Ex classification board II 2 G c Ex e II T3 Marking of the operational conditions of the device group categ...

Страница 5: ...er rotations should not exceed the nominal rotations I Producer is not responsible for wounds injuries body laceration experienced by User or personnel during the improper operational use 4 Technical...

Страница 6: ...6 5 480 130 500 WP 5 D Ex 915 525 60 160 160 194 6 6 5 480 140 WP 7 D Ex 965 570 60 200 160 194 6 6 5 510 155 WP 8 D Ex 990 600 60 200 200 224 8 8 5 535 155 WP 9 D Ex 1030 665 60 200 200 224 8 8 5 580...

Страница 7: ...to lead the electrostatic charges away On the motor housing is located a clamp to fasten the protective cable Additionally on the motor housing is a connection box of the power supply The hemi spheri...

Страница 8: ...l connections are performed correctly b Examine the connection correctness of the electrical connections phases sequence c Check the correctness of the connection between the motor and the PE protecti...

Страница 9: ...nces of the incorrect use damage of the bearings damages caused by corrosion loss in balance of the rotating elements vibrations deformations damages caused by friction Risks which can occur due to im...

Страница 10: ...r supply system Examption from this is a test to carried out on the running fan for example vibration measuring In this case especially follow the rules of Occupational Health and Safety wait until th...

Страница 11: ...ld have destructive effect on the insulation elements constructional elements of the motor and the fan maximum relative humidity should not exceed 80 at the temperature 20 C the ambient temperature sh...

Страница 12: ...12 Ex proof roof fans WP D Ex 18 10 2016...

Страница 13: ...WP 3 D Ex II 2G EExe II T3 3000 0 37 1 0 18 2 BESEL WP 5 D Ex II 2G EExe II T3 3000 0 55 1 4 12 0 BESEL WP 7 D Ex II 2G EExe II T3 3000 1 1 2 4 7 2 BESEL WP 8 D Ex II 2G EExe II T3 3000 1 5 3 5 10 0 I...

Страница 14: ...9 03 2014 The device has been constructed and produced on the basis of subsequent standards PN EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and ri...

Страница 15: ...15 18 10 2016 Ex proof roof fans WP D Ex NOTES...

Страница 16: ...58 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 808W49 WP 3 D Ex 18 10 2016 EN 808W50 WP 5 D Ex 18 10 2016 EN 808W51 WP 7 D Ex 18 10 2016 EN 808W52 WP 8 D Ex 18 1...

Отзывы: