Filtering unit

 

BIG-2000/Ex

 

02.10.2019 

 

 

 

 

                         Fig. No.1  

–  BIG-2000/Ex  –  Flow chart   

 
According to the 99/92/EC ATEX 137 Directive, manufacturer 
carried out the classification of the internal and external zones, 
connected with the explosion hazard during the operation 
of the filtering unit. 
In the 

Fig.  No.2

  is  presented  the  classification  of  the  internal 

zones.  The chamber of filters and the hopper chamber along 
with the waste container have been specified as 

zone 20/21

because in these areas always and in long periods potentially 
explosive atmosphere occurs. 
Whereas, the regeneration chamber is classified as 

zone 22

,  

because  the  dust  occurs  in  this  area  sporadically,  in  case  of 
failures consisting in damage of the cartridge filter or the filter 
mounting. 

 

External zones can be created: 

 

while opening the inspection doors, 

 

during the emptying the waste container. 

They have been classified as 

zone 22

 

 

Fig. No.2 

– Classification ATEX – internal zones 

 

 

STRUCTURE  ADN  FUNCTION 

5.1

  

Structure 

BIG-2000/Ex filtering unit consists of three functional assemblies: 

 

Regeneration chamber, being the upper part of the device, where are located outlets from the cartridge filters and 
Venturi Orifices.  Outside the regeneration chamber is installed the compressed air installation, consisting of: 

 

– 

compressed air tank 

– constructed for operational pressure not exceeding 0,8 MPa, the tank meets the re-

quirements of the 

European Union Directive 87/404/EEG

 and  

90/488/EEG

 

– 

two 

electromagnetic valves of diameter 1”½, designed for regeneration of the  cartridge filters, these valves 

meet the requirements of directives:  

ATEX 94/9/EC

 and 

EMC 89/336/EC

 

Chamber of filters 

– forms the middle part of the filtering unit and contains the cartridge filters.  On the chamber 

housing is located the inspection door, (for filter replacement) and a decompression panel lowering the pressure 
in case of potential explosion.  Outside the chamber is installed a micro-controller 

– to activate the electromagnetic 

valves,  (described in details in Section 7). 

 

Supporting  construction  along  with  the  hopper  chamber.    Underneath  the  hopper  chamber  is  placed  a  waste 
container of capacity 99 litres. 

 

 

Содержание BIG-2000/Ex

Страница 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Страница 2: ...s EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosi...

Страница 3: ...gressive impurities or of the air temperature exceeds 40 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigare...

Страница 4: ...zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 2000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upper part of the device where are located outlets from th...

Страница 5: ...in details described in separate User s Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in test station at t...

Страница 6: ...ices and by a specialised assembly team First put the supporting structure with the hopper chamber The supporting frame should be levelled and its legs fastened firmly to the floor Having installed th...

Страница 7: ...osion risk Especially here is important the hazard of explosion of fire with the purpose of selection of suitable protection sorts Any activities related to the installing necessarily must be performe...

Страница 8: ...is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assembl...

Страница 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Страница 10: ...om dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages of t...

Страница 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Страница 12: ...y the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out it...

Страница 13: ...he manufacturer in the instruction Filtration efficiency is too low Contact the manufacturer 3 Dust is appearing outside the The cartridge filter is damaged Replace the faulty element filtering unit a...

Страница 14: ...d on the antistatic pad rug Near the device do not use mobile phone and other devices emitting electromagnetic waves The filtering unit cannot be submit to modification or complemented with functional...

Страница 15: ...r device failures caused during the use which is in contradiction with the purpose of application and with the present Use and Maintenance Manual malfunctions resulting from the improper transport sto...

Страница 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Отзывы: