Klimawent BIG-2000/Ex Скачать руководство пользователя страница 1

 

 

EN 

 

USE AND MAINTENANCE MANUAL 

 

 

 

  

Filtering unit  BIG-2000/Ex 

 

 

ATEX marking: 

 

 

II 3 D Ex tD A22 T200

ºC

 

   

 

 

 

 

 

Contents

:

 

 

INTRODUCTION ......................................................................................................................................................... 2

 

 

PURPOSE ................................................................................................................................................................... 2

 

 

RESERVATIONS  OF  MANUFACTURER .................................................................................................................. 3

 

 

TECHNICAL  DATA ..................................................................................................................................................... 3

 

 

STRUCTURE  ADN  FUNCTION ................................................................................................................................. 4

 

 

ASSEMBLY  AND  STARTUP ..................................................................................................................................... 6

 

 

OPERATIONAL  USE .................................................................................................................................................. 8

 

 

TROUBLESHOOTING  GUIDE .................................................................................................................................. 13

 

 

MAINTENANCE  AND  REPAIR ................................................................................................................................ 13

 

 

OCCUPATIONAL  HEALTH  AND SAFETY .............................................................................................................. 14

 

 

TRANSPORT   AND  STORAGE ............................................................................................................................... 14

 

 

TERMS  OF  WARRANTY ......................................................................................................................................... 15

 

 

DECLARATION  OF  CONFORMITY ........................................................................................................................ 16

 

 

02

.

10

.

2

0

1

9

 

Producer: 

KLIMAWENT S.A. 

81-

571 Gdynia, ul. Chwaszczyńska 194 

tel. 58 629 64 80, 58 771 43 40 
fax 58 629 64 19 
email

[email protected]

 

 

www.klimawent.com.pl

 

issue:

 October 2019

 

 

 

Содержание BIG-2000/Ex

Страница 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Страница 2: ...s EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosi...

Страница 3: ...gressive impurities or of the air temperature exceeds 40 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigare...

Страница 4: ...zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 2000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upper part of the device where are located outlets from th...

Страница 5: ...in details described in separate User s Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in test station at t...

Страница 6: ...ices and by a specialised assembly team First put the supporting structure with the hopper chamber The supporting frame should be levelled and its legs fastened firmly to the floor Having installed th...

Страница 7: ...osion risk Especially here is important the hazard of explosion of fire with the purpose of selection of suitable protection sorts Any activities related to the installing necessarily must be performe...

Страница 8: ...is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assembl...

Страница 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Страница 10: ...om dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages of t...

Страница 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Страница 12: ...y the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out it...

Страница 13: ...he manufacturer in the instruction Filtration efficiency is too low Contact the manufacturer 3 Dust is appearing outside the The cartridge filter is damaged Replace the faulty element filtering unit a...

Страница 14: ...d on the antistatic pad rug Near the device do not use mobile phone and other devices emitting electromagnetic waves The filtering unit cannot be submit to modification or complemented with functional...

Страница 15: ...r device failures caused during the use which is in contradiction with the purpose of application and with the present Use and Maintenance Manual malfunctions resulting from the improper transport sto...

Страница 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Отзывы: