background image

                                   2 

                                              

cyclone separator

  STORM-H

-{

1000

;

 2000

;

 5000

}

                

 

       

05.11.2019

 

   

 

1.  Introductory Remarks 

The purpose of the present

  

Use

 and Maintenance Manual  is to supply User  with directions wi- 

thin the range  of application,  installation,  start-up  and  the use of the  

STORM-H

 

cyclone se-

 

parator

.

 

Installing, start up and operational use  are exclusively admissible after getting acquaint- 
ted with the contents of the Use and Maintenance Manual

With regard to continuity of work carried on 

improvement

 of our

 

products,  we reserve for oursel- 

ves the revision possibility of the

 draft  and

  

technological changes  improving their functional fea-

tures and safety. 

Construction of the 

STORM-H

 

cyclone separator  meets

 the 

requirements of the current state

 

of te-

chnology

  

as well as the safety and health assurances included in: 

  2006/42/EC

 

Machinery Directive 

of the European Parliament 

and of the Council of

 May 17

th

2006  on machinery 

– amending the 95/16/EC (recast)

  /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

  2014/35/EC Directive  

of the European Parliament  and of the Council of 26 February, 2014   

on the harmonisation  of the

 laws  of 

the Member States  relating to the making available

 on the 

market of electrical equipment designed for use within certain voltage limits.    

/

Journal of Laws 

EC L96  of 29.03.2014

/

 

The appliance meets the requirements included in: 

 

2009/125/EC (ErP)

 

Directive

 

of the European Parliament  and of the Council of October 21

th

2009 establishing a framework for the setting  of ecodesign requirements  for energy-related 
products / 

Journal of Laws L 285 of 31.10.2009

 

 

327/2011

 (

EU

Regulation  

of 

March 30

th

, 2011  on implementing

 the 

2009/125/EC Directive

 

 

of the European Parliament 

and of the Council  with regard

 

to ecodesign requirements

 for fans 

driven by motors with an electric input power between 125W and 500 kW 

Journal of Laws L  No. 90  of 06.04.2011

 /

 

Additionally, the appliance meets following harmonized standard: 
● 

EN ISO-12100:2012 

 
 

 

“Safety of 

machinery

  

– 

Basic concepts, general

 principles  

 

 

 

for design.  Risk assessment and risk reduction” 

● 

EN 60204-1:2018-12

 

 
 

 

“Safety of machinery – Electrical equipment of machines   

 

 

 

Part 1:  

General requirements” 

● 

EN ISO 13857:2010 

 
 

 

“Safety of machinery – Safe distances to prevent hazard  

 

 

 

zones being re

ached by upper and lower limbs” 

2.  Application 

STORM-H cyclone separators

 

are efficient in cleaning the 

dry

 air from contamination of dust of 

particle diameter above 5 

m. They belong to vacuum device group. Separation proceeds here 

on the basis  of centrifugal force phenomenon,  whereby the extracted dust  accumulates in the 
waste container (located underneath the cyclone separator).   
In case of coarse dust particles: the STORM-H cyclone separator can work as a final filter, whe- 
reas, for fine dust extraction, it can be used as a pre-filter, where it is connected in a line before 
the fine filter of similar volume flow.   
The dust separating efficiency oscillates within limits 95 

– 99%. 

Separators are manufactured in versions: 
– 

with a fan 

(STORM-5000-H, STORM-2000-H, STORM-1000-H) or  

– 

without fan 

(STORM-5000 SOFT-H, STORM-2000 SOFT-H, STORM-1000 SOFT-H).  

In a version without the fan, the feature resistance 

of the separator

 must be overcome by the 

final fan of the cooperating filtering unit. 

3.  Reservations of Producer 

A

.

 

Manufacturer accepts no liability  for any consequences following from the operational use 
that is in contradiction to the purpose of application. 

B

.

 

Installing of any additional elements  that are not belonging  to the normal device structure 
(or accessory set) is not acceptable. 

 

 

Содержание 802O14

Страница 1: ...3 40 802O14 STORM 1000 SOFT H 05 11 2019 EN e mail klimawent klimawent com pl 802O15 STORM 2000 SOFT H 05 11 2019 EN www klimawent com pl 802O16 STORM 5000 SOFT H 05 11 2019 EN Contents 1 Introductory...

Страница 2: ...ropean Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Addition...

Страница 3: ...maximum impeller rotations should not exceed nominal rotations I In the course of operational use pay attention that any ignition sources i e glowing cigarettebutts embers should not get into cyclone...

Страница 4: ...4 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 SOFT H STORM 2000 H...

Страница 5: ...5 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 2000 SOFT H STORM 5000 H...

Страница 6: ...version STORM SOFT H 6 sound absorbing set for version STORM H on separate order 7 motor protective switch for versions STORM 1000 H STORM 2000 H or motor starter for version STORM 5000 H The dust se...

Страница 7: ...7 05 11 2019 cyclone separator STORM H 1000 2000 5000 Fig No 1 STORM H and STORM SOFT H Structure...

Страница 8: ...8 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 H STORM 2000 H STORM 5000 H Fig No 2 STORM H Dimensions...

Страница 9: ...9 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 1000SOFT H STORM 2000 SOFT H STORM 5000 SOFT H Fig No 3 STORM SOFT H Dimensions...

Страница 10: ...industrial rooms They can be also used outside the building but with additional protection against atmospheric factors weather conditions i e roofing The separator must be placed stably on the even fl...

Страница 11: ...tion where the cyclone separator serves as a final filter the fan outlet ought to be equipped with a sound absorbing set delivery on separate order Whereas when the cyclone works as a pre filter it is...

Страница 12: ...itoring When the waste container is filled up switch off the device and empty the container according to the instructions on pages 12 14 Having cleaned the con tainer put it underneath the cyclone sep...

Страница 13: ...aded over filled see Fig No 7 9 Maintenance The construction provides long lasting and efficient work without routing technical supervision In the course of operational use simply it is sufficient to...

Страница 14: ...ventilation 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User...

Страница 15: ...of October 21th 2009 establishing a framework for the setting of ecodesign requirements for energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on imp...

Страница 16: ...16 cyclone separator STORM H 1000 2000 5000 05 11 2019 NOTES...