Klimawent
– the warranty of highest quality at attractive price
6 of 12
Ozone generator KILLVIR-48
25.01.2021
F.
Secure the entrance to the room and mark with an information sign with the appropriate content, e.g.
DO NOT ENTER! OZONATION
or
NO ENTRY! DISINFECTION WITH OZONE
.
! WARNING
DO NOT go into the room when the light is on warning "DISINFECTION – DO NOT ENTER"
without adequate protection!
Operation
A.
The device will automatically finish ozonation after the set time has elapsed, and the fan will continue
to work for another 30 minutes, mixing the air in the room.
! CAUTION
The fan of the device continues to work 30 minutes after the end of ozonation, which is
signalled by the warning light "DISINFECTION - DO NOT ENTER".
When the time reaches 0 value, the device stops working, and the time on the display will
return to the previously set time.
B.
After the warning light goes out, you can enter the room and take the device away, observing the safety
rules described below in the warning (Note 1 Warning regarding ozonation) and point
10 - OHS
INSTRUCTIONS
.
Turning off the device
A.
Turn the
“POWER SWITCH”
switch to the position
O
. The switch turns off. The device will stop
working.
B.
Disconnect the power cord from the power socket.
C.
Ventilate the room for at least 15 minutes.
! CAUTION
If no one is left in the room after ozonation, you can leave it unventilated and let the ozone
decompose itself. Then the room will be ready for use after at least 1 hour.