INTRODUCTION 

This user manual is intended for the users of the 

KILLVIR-48

 device. Its purpose is to provide the users with 

instructions on the use, assembly, commissioning, and operation of the device. 

 

NOTICE 

Carefully read this manual before installing the device at the workplace and using it. 

Due to the continuous improvement of its products, the manufacturer reserves the right to introduce 
construction changes to increase the utility values and safety of use. 

 
The design of the 

KILLVIR-48

 device takes into account the current state of knowledge and technology level 

and  is  following  normative  principles  and  regulations,  and  above  all  with  the  principles  of  safety  and  health 
protection  set  out  in  the  following  legal  acts  and  also  meets  the  requirements  of  the  following  harmonised 

standards: 

 

Directive 2006/42/EC (MD) 

 

Directive 2014/35/EU (LVD) 

 

Directive 2014/30/EU (EMC) 

 

PN-EN ISO-12100:2012  

 

PN-EN 60204-1:2018-12  

 

PN-EN 60034-1:2011 

 

PN-EN 60529:2003/A2:2014-07 

 

PN-EN ISO-13857:2020-03 

 

PN-EN IEC 61000-6-1:2019-03 

 

PN-EN ISO 14123-1:2016-03 

 

PN-EN 1005-2+A1:2010 

 

PN-EN 842+A1:2010 

 

APPLICATION 

The 

KILLVIR-48

 ozone generator is designed for ozonation and deodorization of closed rooms with a volume 

of up to 450 m3. 

 

NOTICE 

The KILLVIR-48 ozone generator can be used to inactivate virus particles in the air while maintaining 
the appropriate proportions of the exposure time of the atmosphere inside the room to ozone and 
the size of the room. 

 

Table 1 Approximate ozonation times 

The size of the room 

Ozonation time 

150 m2 (volume ~450m3) 

90 min 

75 m2 (volume ~225m3) 

45 min 

 

MANUFACTURER'S DISCLAIMER 

 

The manufacturer is not liable for damages resulting from the incorrect connection of the power supply 
and improper use of the device.  

 

It is unacceptable to install any additional elements not included in the device or equipment on the device. 

 

Unauthorized alterations and modifications to the device are not allowed. 

 

The device should be operated and repaired by an authorized and trained person. 

 

Protect all machine components against mechanical damage. 

 

The manufacturer is not responsible for bodily injury resulting from incorrect use. 

 

Protect people, animals and plants from the harmful effects of ozone. 

 

Protect ozone-sensitive materials. 

 

Protect the device from falling as it may permanently damage the generator. 

 

Содержание 800Z01

Страница 1: ...USER MANUAL 800Z01 Ozone generator KILLVIR 48 KLIMAWENT S A Poland 194 Chwaszczy ska street 81 571 Gdynia phone 48 58 629 64 80 fax 48 58 629 64 19 e mail klimawent klimawent com pl www klimawent com...

Страница 2: ...TION 3 APPLICATION 3 MANUFACTURER S DISCLAIMER 3 TECHNICAL DATA 4 STRUCTURE AND FUNCTION 4 INSTALLATION AND COMMISSIONING 4 OPERATION 5 TROUBLESHOOTING GUIDE 7 MAINTENANCE AND RECYCLING INSTRUCTIONS 7...

Страница 3: ...00 6 1 2019 03 PN EN ISO 14123 1 2016 03 PN EN 1005 2 A1 2010 PN EN 842 A1 2010 APPLICATION The KILLVIR 48 ozone generator is designed for ozonation and deodorization of closed rooms with a volume of...

Страница 4: ...Principle of operation and function The principle of operation of the KILLVIR 48 device is based on the production of ozone in a volatile state as a result of the phenomenon of partial discharges on...

Страница 5: ...Picture 1 Control panel Procedure Installation A Place the device as high as possible and in the centre of the room B Before starting check that the power cord is not damaged NOTICE Ozone is a gas he...

Страница 6: ...after the end of ozonation which is signalled by the warning light DISINFECTION DO NOT ENTER When the time reaches 0 value the device stops working and the time on the display will return to the prev...

Страница 7: ...ng of waste should be applied No part of the construction of the device belongs to the hazardous waste group OHS MANUAL CAUTION The device according to the definition is a machine and meets the safety...

Страница 8: ...ot to enter it earlier than 1 hour after the end of ozonation STORAGE The device should be stored according to the following rules A The device should be stored in a transport packaging that protects...

Страница 9: ...with the atmosphere of the ozonated room Immediately after ozonation ventilate the room for at least 15 minutes until the concentration of ozone in the room is reduced to a safe level i e 0 1 ppm ozo...

Страница 10: ...NT S A hereby declares that the product Ozone generator type model KILLVIR 48 Serial number ___________________ Year of production ___________________ Meets the requirements of the subsequent European...

Страница 11: ...Klimawent the warranty of highest quality at attractive price 25 01 2021 Ozone generator KILLVIR 48 11 of 12 WIRING DIAGRAMS Diagram 1 Electrical connections...

Страница 12: ...ty at attractive price 12 of 12 Ozone generator KILLVIR 48 25 01 2021 KLIMAWENT S A Poland 194 Chwaszczy ska street 81 571 Gdynia phone 48 58 629 64 80 fax 48 58 629 64 19 e mail klimawent klimawent c...

Отзывы: