background image

14

If you suspect something is wrong with your Heat Pump?

Before you call for service, fill out below. (Reg. Card

is sent to

NICO Norge __)

Send to your Dealer and keep a copy in front of you when you call.

Model written on Heat Pump: ___________________ Serial No:______________

Delivered from Company: ______________________________________________

Installation date: ________ Installed: Outside __ Inside__ inside in a shed __

Distance to obstacles: Front ___ m

Back ____ m

Top ____ m

Pool Surface Area ________ m2

Pool is: Covered __

Uncovered __

Other Heating system for the Pool: Yes __ No __ Desired Pool temp ____C

Normal Air Temperature: ______C

Normaly: Dry Air __ Humid Air __

Pool Filter Pump: ________ kW. Filter is Clean __ Pressure on filter: ____

Max Pool Temperature reached_____ C°

Desired Pool Temp _____C°.

Is there Ground Water around the pool? YES__ NO__ DON’T KNOW__

Any Failure Code on Display _____. Check Settings. See Default Settings:

Observed Settings: ____________________________________________

Is the heat pump: Running __ Running sometimes __ Not running at all ___

Is the heat pump: Heating __ Not Heating enough __ Not heating at all __

Is the fan running? YES__ NO__ Is there ice on “Radiator” YES__ NO__

Is there Cold Air coming out from Radiator: YES__ NO__ DON’T KNOW__

Are there leaves or dirt on the fins on the “Radiator” YES__ NO__

Gas Pressure on heat pump? Running _____Pa Not running _____ Pa

Do Following:

Switch Main Power OFF. Wait 3 min. Power ON, Heat Pump ON. > Listen:

Does the

fan

start within 2 Min? YES__ NO__

Does the

compressor

start within next 2 Min? YES__ NO

Check:

Voltage on Heat Pump connections: Standby __V. ON__V. Running __V

Fuse for Heat Pump _______A Cable size from Fuse to Heat Pump _____mm2

Are the Fuse if Type: Slow Blow / Motor Fuse / Yes___ No___

Parameter Settings

If Possible read, and Note all parameter settings. (See Page 6)

0 = _____

1 = _____

2 = _____

3 = _____

4 = _____

5 = _____

6 = _____

7 = _____

8 = _____

9 = _____

A = _____

B = _____

C = _____ D = _____

E = _____

F = _____

NOTES___________________________________________________________

Содержание KT10X

Страница 1: ...1 ...

Страница 2: ... professional technician It is strongly advised to place a protective guard around the unit to keep children away from the heat pump An authorized electrician must connect the Heat Pump to the power 230V 1ph or 400V 3ph Remarks Make sure that you have enough power See page 15 Cable table 380 400V 3ph 50Hz 230V 1ph 50Hz WATER PUMP POWER SUPPLY POWER SUPPLY WATER PUMP See diagram above for minimum d...

Страница 3: ...ilter pump off The unit should also switch off automatically 5 The unit and the filter pump should run 24 hours a day until the desired pool water temperature has been reached Once the set temperature is reached the unit will switch itself off As long as the filter pump is running the unit will restart automatically when the temperature of the pool water drops more than 1 C below the set temperatu...

Страница 4: ...keep your desired pool temperature at all times Example If you want your pool to be 30 C A If the pool water is below 29 C the heat pump will start heating B When the temperature reaches 31 C the heat pump will stop C If the temperature in your pool continues to rise and passes 32 C the heat pump will start again BUT in Cooling Mode and cool down to 30 C D If now the temperature continues to drop ...

Страница 5: ... MODE for 5 sec The display will start to blink both digits The first digit indicates the parameter The second digit s indicate the value of the parameter This reading mode will be deactivated if you do not press a button for 10 sec By pressing or you will see parameters from 0 to F one by one Make a note of each parameter for your records Wait 10 sec and this function is deactivated you are back ...

Страница 6: ...flash to indicate that they can be modified by pressing or 2 Press again minute digits will flash to indicate that they can be modified by pressing or 3 Press again for final confirmation of time setting Once time has been set LED display will show time when heat pump is on standby ...

Страница 7: ...to activate timer start or to activate timer stop the corresponding indicator light will be flashing Press to cancel timer start or timer stop INFO The parameter can be changed by a skilled person A code is needed to do so The procedure for this is in the Main Manual The keypad can be locked to prevent unauthorized use or changes of the heat pump The procedure for this is in the Main Manual If the...

Страница 8: ...ilter unit water inlet on heat pump 3 Start the filter pump to start the water flow to the heat pump Adjust the by pass so there is enough water running through the heat pump Normally on a small filter system the by pass can be closed so all circulated water goes through the heat pump 4 Reconnect the electrical power supply to the heat pump and turn the heat pump ON 13 Check up Our heat pumps have...

Страница 9: ...nning If the water stops running out it is condensation AN EVEN QUICKER WAY IS TO TEST THE DRAIN WATER FOR CHLORINE If no chlorine is detected the drain water is a result of condensation Also make sure that the air in and out passages are free and prevent air out from immediately re entering to the air in It is important to have min 2 5m free space at the air out side of the heat pump 14 Maintenan...

Страница 10: ...10 The manometer is showing the pressure at 14 ambient air and the pump is not running standby mode ...

Страница 11: ... heat pump to prevent damage to the compressor If the heat pump has been transported and carried all the time with the feet down it can be started immediately Note Switch off the power before carrying out any maintenance or repairs IMPORTANT REMARK if a malfunction cannot be resolved immediately in order to analyse the problem we will need to know the message error code that is showing on the disp...

Страница 12: ...eeze protection for cooling Refer to PP06 Refer to PP06 PP07 PP7 Winter anti freeze protection Ⅰ No action required PP07 PP7 Winter anti freeze protection Ⅱ No action required EE03 EE3 Water flow switch failure 1 Check if wiring connection of flow switch is in correct position 2 Check water flow 3 Check if flow switch is broken 4 Check if water pump is working 1 Reconnect the wiring 2 Increase wat...

Страница 13: ...13 ...

Страница 14: ...Default Settings Observed Settings ____________________________________________ Is the heat pump Running __ Running sometimes __ Not running at all ___ Is the heat pump Heating __ Not Heating enough __ Not heating at all __ Is the fan running YES__ NO__ Is there ice on Radiator YES__ NO__ Is there Cold Air coming out from Radiator YES__ NO__ DON T KNOW__ Are there leaves or dirt on the fins on the...

Страница 15: ... The heat pump stops Error code EE3 Too little water flow Check Filter and filter Pump Air in the Filter system Water Flow Switch defect d The heat pumps stops and starts frequently Too little water flow Air leakage in pipes on suction side Check Filter and filter Pump Air in the Filter system Water Flow Switch defect e Heat pump does not work periodically Weak power Supply To long Supply Cable To...

Страница 16: ...16 ...

Отзывы: