background image

9

Turn off  the appliance
first before disconnecting
from power supply.

It is necessary to clean the air filter after using 
it for about 100 hours.
Clean it as follows:

Front panel maintenance

Air filter maintenance

Cut off the 
power supply

Never use volatile substance 
such as gasoline or 
polishing powder to clean 
the appliance.

Clean and re-install 
the air filter.

Close the front panel again.

shock!

Electric 

Dangerous!

Wipe with a soft and 
dry cloth.

Use lukewarm water(below 
85

º F

) to clean if  the 

appliance is very dirty.

Never sprinkle water 
onto the indoor unit

Reinstall and shut the 
front panel.

Reinstall and shut the front 
panel by pressing position "b" downward.

If the dirt is conspicuous,
wash it with a solution of
detergent in lukewarm water.
After cleaning, dry well in 
shade.

 Clean the air filter every two weeks 
 if the air conditioner operates in an
 extremely dusty environment.

Stop the appliance 
and remove the 
air filter.

1.Open the front panel.
2.Press the handle of the filter gently
   from the front.
3. Grasp the handle and slide out the filter.

soft cloth to 
    clean it.

Use a dry and 

Grasp position "a" 
and pull outward to 
remove the  front panel.

a

a

b

b

Maintenance

At the end of the season

Set temperature to 86

º F

 for about half a day

and perform the Cooling operation to dry
well the Unit's inside.

Stop the unit operation and then 
turn off the power switch for  afety 
and for saving electric energy.

s

Clean both Indoor and Outdoor Units.

Clean and reinstall the air filters.

Remove batteries from the remote controller.

Dry the inside
of the unit.

OFF

ON

At the beginning of the season

Make sure there are no obstacles blocking
the airflow around the air intake and air 
outlet openings of the Indoor and Outdoor 
Units

Check the installation base for corrosion or rust.

Make sure the earth 
wire is not broken or 
disconnected

Make sure the air filters are cleaned.

Turn on the power switch.

Insert batteries into the remote controller.

Содержание SPLIT AIR-CONDITIONER

Страница 1: ...ome this Owner s Manual should be read carefully be fore using your air conditioner Afterre ading st ore it in a safe place P lease refer to the manual for questions on useo rin the event that any irr...

Страница 2: ...s any button when the flashes If you dont press any button within 10 seconds the remote controller is pre set as Heat Pump automatically the symbol will flash from Cool and HEAT alternatively heating...

Страница 3: ...us injury etc SLEEP FAN TIMER SWING ON OFF MODE MED LO SWING AUTO HI DRY FAN HEAT COOL FEEL SLEEP TIMER ON OFF Use correct power supply in accordance with the rating plate requirement Otherwise seriou...

Страница 4: ...ntake Air Intake Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Electrostatic Filter optional Charcoal Filter optional Air Filter Remote Controller Front Panel Emergency Panel Disp...

Страница 5: ...t when the remote controller is out of work If there is any difference between the sketch map and the substantiality please subject to the substantiality R unIndic ator It is on during operation S lee...

Страница 6: ...ortable SLEEP Used to start and stop operation Used to adjust airflow direction Used to select TIMER operation Signal Transmitting Window Transmits signals to the system Setting Display Transmitting d...

Страница 7: ...or each time the batteries are replaced as they are discharged the remote control mades a short Auto Test all the symbols can be displayed are shown on the screen and keep 2 seconds then the symbol wi...

Страница 8: ...m air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 23 ft when pointing at signal receptor of indoor unit Remote...

Страница 9: ...possible with the button or the button Press the MODE select button Move the MODE to the FEEL position 1 2 Operates by selecting automatically the operation mode HEAT DRY FAN COOL depending on the ro...

Страница 10: ...nds SLEEP operation is switched from Normal SLEEP to SLEEP alternatively Comfortable Used to set or cancel sleep operation This function is invalid in fan and dehumidify mode This function is invalid...

Страница 11: ...usty environment Stop the appliance and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter soft cloth to cl...

Страница 12: ...5 minutes later In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrostin...

Страница 13: ...e power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may come from another source such as furniture cigarette etc which is sucked in the unit...

Страница 14: ...hould be over 6 in should be over 79 in should be over 12 in Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple...

Страница 15: ...re is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall accord...

Страница 16: ...a sleeve through the wall hole to keep the wall tidy and clean Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the 2...

Страница 17: ...lation tube Power cord 1 for heat pump Power cord Defrost cable for heat pump Drain hose prepared by user A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Bas...

Страница 18: ...ble thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be s...

Страница 19: ...ct the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture...

Страница 20: ...tdoor unit Connetting indoor unit Connetting power Indoor Unit 3 N 1 2 L Connetting outdoor unit Indoor Unit N 1 L Outdoor Unit N 1 L N L Outdoor Unit 3 N 1 2 L N L 1 N 1 2 3N Cooling Heating 12 3N Co...

Страница 21: ...o a double pole switching device with contact separation of at least 1 8 in placed in an accessible position even after installation NOTE NOTE Test Running Connect to the power source check if the fun...

Страница 22: ...5 594 4972 Fax 305 675 2212 www klimaire com sales klimaire com 2190 NW 89 Place Doral FL 33172 USA The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2010 Klimaire Product...

Отзывы: