24
INSTALLATION MANUAL - Indoor Unit installation
The copper pipe should be set through the wall to outside
when installing the indoor unit, for quick-connecting
product.
Run the piping in the direction of the wall hole, and put
the drain pipe at the bottom, then bind the copper pipes
and the drain pipe and the power cables together with
the tape, so that water can flow away freely.
Do not remove the cap from the pipe until connecting
it, to avoid dampness or dirt from entering.
If the pipe is bent or pulled too often, it will become
stiff. Do not bend the pipe more than three times at
one point.
When extending the rolled pipe, straighten the pipe by
unwinding it gently as shown in the picture.
Unrolling the pipes
Indoor unit condensate water drainage
The indoor unit condensed water drainage is fundamen-
tal for the success of the installation.
1. Place the drain hose below the piping, taking care not
to create siphons.
2. The drain hose must slant downwards to aid drainage.
3. Do not bend the drain hose or leave it protruding or
twisted and do not put the end of it in water. If an
extension is connected to the drain hose, ensure that
it is lagged when it passes into the indoor unit.
4. If the piping is installed to the right, the pipes, power
cable and drain hose must be lagged and secured onto
the rear of the unit with a pipe connection.
A) Insert the pipe connection into the relative slot.
B) Press to join the pipe connection to the base.
YES
Refrigerant piping setting position
NO
NO
NO
YES
Extending the rolled pipe
Condensed water drain pipe
(at the bottom of bundle)
Sleeve
Insulating covering
Mounting plate
6
or
150mm
6
or
150mm
6
or
150mm
Inclined donwards
1.
2.