3-8
CHAPTER 3 Preparation for Use
Series 5000 V2 Sonar System Operations and Maintenance Manual
P/N 11214512, Rev. 04
T/F TRIG:
BNC connector that connects to an external sonar
system and is used to trigger the sonar of that system
at the start of each ping cycle. Provides a TTL
compatible, 100-µs wide output pulse.
TRIG A:
BNC connector that connects to an ultra short
baseline navigation system (USBL). Provides a TTL
compatible, 100-µs wide output pulse with each
trigger of the optional responder.
1 PPS IN:
BNC connector that is used to input 1 PPS (one
pulse per second) signals.
TOWFISH:
Type N coaxial connector that connects to the
towfish using a deck cable or a tow cable.
AC INPUT:
IEC type connector that connects to the AC power
source.
3.5.2 SonarPro Workstation Connections
All the connections to the SonarPro Workstation are made to connectors on the
back panel which is shown in Figure 3-2.
The SonarPro Workstation connectors are the following:
USB:
USB connectors (4, plus 2 on the front panel). Any
two connect to the keyboard and the mouse. The
front panel USB connectors are shown in Figure 3-4
on page 3-14.
DVI:
DVI connector that connects to the monitor.
ETHERNET:
RJ-45 connectors (2). Any one connects to the LAN
connector on the TPU.
AC INPUT:
IEC type AC input connector that connects to the
AC power source.
Содержание 5000 V2 Series
Страница 24: ......
Страница 48: ......
Страница 62: ......
Страница 73: ...A 3 Figure A 1 Cable Length vs Towfish Depth Graph 1...
Страница 75: ...A 5 Figure A 3 Cable Length vs Towfish Depth Graph 3...
Страница 77: ...A 7 Figure A 5 Cable Length vs Towfish Depth Graph 5...
Страница 78: ......
Страница 82: ......
Страница 88: ......
Страница 92: ......
Страница 95: ...E 3...
Страница 97: ...E 5...
Страница 99: ...E 7...
Страница 101: ...E 9...
Страница 103: ...E 11...
Страница 105: ...E 13...
Страница 107: ...E 15...
Страница 109: ...E 17...
Страница 111: ...E 19...