ENGLISH
8.
Non Contact Voltage (NCV): > 25V AC
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
AT
Auto Range Active
O.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
MAX
Maximum Reading
%
Duty Cycle Mode
Frequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms
Diode Test
F
Capacitance in Farads
Continuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 600V
0.1mV ˜ 0.1V
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload Protection:
1000V
AC Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 750V
0.1mV ˜ 1V
± (2.0% + 5 digits)
Overload Protection:
750V RMS
Frequency Response:
45 to 400 Hz
Minimum Voltage for Frequency Measurement:
200mV
Response:
True RMS
DC Current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (1.2% + 3 digits)
2000µA
1µA
60A
0.01A
± (2.5% + 15 digits)
600A ~ 1000A
0.1A ~ 1A
± (1.5% + 8 digits)