I
J
FEATURE DETAILS
A.
Use CAT IV 600 rated leads or higher.
Do not attempt to measure more than 1000V DC or 750V AC or 2000µA.
B.
Keep hands below line when measuring high current levels.
C.
Auto Power-Off (Apo)
• Device will power off after 30 minutes non-use.
• Turn the dial or press a button to wake.
• Disabled during Max / Min function.
• Holding Select button while turning on disables Auto Power-Off.
D.
Select Functionality Button
• Quick press (<0.5 sec):
»
Switch between AC and DC.
»
Switch between
and .
• Long press (>1 sec):
»
Switch between AC, Frequency, and Duty Cycle modes.
»
Zero the DC current clamp reading.
E.
Hold / Backlight / Worklight
• Press to hold the current input on the display.
• Press again to return to live reading.
• Press for 2 seconds to enable / disable lights.
• Using lights decreases battery life.
F.
Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
•
AT
is displayed on LCD only during auto ranging mode.
G.
Max / Min Hold
• Press to enter Max / Min mode; the largest and smallest
values will be saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum readings.
• Press for 2 seconds to return to live reading and clear
the stored maximum and minimum values.
B
8
4
1
C
D
A
K
E
F
G
H
4