FEATURE DETAILS

A. 

Use CAT IV 600 rated leads or higher. 

Do not attempt to measure more than 1000V DC or 750V AC or 2000µA.

B. 

Keep hands below line when measuring high current levels.

C. 

Auto Power-Off (Apo)

•  Device will power off after 30 minutes non-use.

•  Turn the dial or press a button to wake.

•  Disabled during Max / Min function.

•  Holding Select button while turning on disables Auto Power-Off.

D. 

Select Functionality Button

•  Quick press (<0.5 sec):

 

»

Switch between AC and DC.

 

»

Switch between 

 and  .

•  Long press (>1 sec):

 

»

Switch between AC, Frequency, and Duty Cycle modes.

 

»

Zero the DC current clamp reading.

E. 

Hold / Backlight / Worklight

•  Press to hold the current input on the display.

•  Press again to return to live reading.

•  Press for 2 seconds to enable / disable lights.

•  Using lights decreases battery life.

F. 

Auto / Manual Range

•  Press repeatedly to cycle through manual ranges.

•  Press for 2 seconds to return to auto ranging mode.

• 

AT

 is displayed on LCD only during auto ranging mode.

G. 

Max / Min Hold

•  Press to enter Max / Min mode; the largest and smallest  

values will be saved while in this mode.

•  Press repeatedly to alternate between the maximum and minimum readings.

•  Press for 2 seconds to return to live reading and clear  

the stored maximum and minimum values.

B

8

4

1

C

D

A

K

E

F

G

H

4

Содержание CL2500

Страница 1: ...Instruction Manual F o r P r o f e s s i o n a l s S i n c e 1 8 5 7 CL2500 1000A AC DC TRUE RMS DC ZERO BACKLIGHT WORKLIGHT BAR GRAPH MAX MIN HOLD 3 5 6 DIGIT 5999 COUNT LCD AUTO MANUAL RANGE NON CO...

Страница 2: ...eath Before each use verify meter operation by measuring a known voltage or current Never use the meter on a circuit with voltages that exceed the category based rating of this meter Do not use the me...

Страница 3: ...ncy and Duty Cycle modes Zero the DC current clamp reading E Hold Backlight Worklight Press to hold the current input on the display Press again to return to live reading Press for 2 seconds to enable...

Страница 4: ...han the digital display The scale of the bar graph is zero to the maximum reading of the selected range FUNCTION INSTRUCTIONS 7 1 6 2 3 5 1 AC DC Current large 1000A Features ZERO DC MAX MIN RANGE HOL...

Страница 5: ...ve circuit 6 Capacitance 6000 F Features HOLD Safely discharge capacitor before measurement Reading may take up to 60 seconds for large capacitors 7 Diode Continuity Display shows Forward voltage drop...

Страница 6: ...est Relative Zero Mode n Nano 10 9 Micro 10 6 m Milli 10 3 k Kilo 103 M Mega 106 ELECTRICAL SPECIFICATIONS DC Voltage Measurement Range Resolution Accuracy 600mV 600V 0 1mV 0 1V 0 5 4 digits 1000V 1V...

Страница 7: ...0 4 digits 60M 0 01M 2 0 4 digits Overload Protection 600V RMS Capacitance Measurement Range Resolution Accuracy 60nF 6000 F 0 01nF 1 F 3 5 6 digits Overload Protection 600V RMS Frequency Measurement...

Страница 8: ...s shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss Some...

Отзывы: