    High Power Amplifier P

RO

 A 2000

1. Basic Information

The K+H P

RO

 A 2000 is a highest performance

class AB high power amplifier. Most sophisticated
protection functions and high power reserves make
this amplifier the first choice for all applications.
Special features are: built in versatile limiter, which
can be disabled in part, 3 slots for expansion modules
such as controller for switching over to a redundant
power amplifier in case of failure (HAVARIE), remote
control, remote diagnosis, audio controller, parametric
2-band EQ, add on digital audio input interface and
high performance balancing input transformers. 100/
70 V output transformers are available as separate
units.
Basicly the P

RO

 A 2000 is designed for 4 Ohms load

impedance under hard conditions too, but dependant
on environmental effects and audio material, it can
drive loads down to 1.8 Ohms without loss in
performance. Safe operation of the amplifier itsself
and the connected speakers under all conditions and
faults is secured by costly protection circuits. Before
switching off the amplifier or the speakers, these
circuits try to go back to a safe operation condition in
reducing the output power by means of the thermal
and current limiters. This is very smoothly done and
without increasing THD. Not before these steps will
not do there will be a switch off. If any high frequency
(e. g. feedback to preamplifier) or DC-signals are
detected at the power output, the protection circuit
switches off both amplifier and speaker outputs
immediately.

2. Installation

2.1 It is absolutely essential that you read
and observe the Safety Instructions on
page 2 before connecting or using this
device.

2.2 Operating conditions

The K+H model P

RO

 A 2000  high power amplifier is

intended for use over a range of ambient temperatures
from +10° C to +40° C (+50° F to +104° F). During
transport or storage, temperatures from -25° C to +70°
C (-13° F to 158° F) are permissible.

2.3 Rack Installation

When installing the P

RO

 A 2000 to a rack it is

recommended to use sidewise bearings. In any case
the rear fastening angles have to be fixed to the rack
too.

Warning!

Because of the heavy weight the front
panel alone cannot carry the P

RO

 A 2000!

Please take care of sufficient ventilation
at both sides of the amplifier see figure 3:

Fig. 3 P

RO

 A 2000 airflow

2.4 Cooling

The P

RO

 A 2000 is equipped with a most efficient push-

pull cooling system, which allows for sustained
continous operation at a 4 Ohms load. So the P

RO

 A

2000 can be operated under hard conditions without
any air conditioning. Of course the ventilation in the
rack has to be sufficient.
The cooling air is drawn in at both sides and the cover
plates on top and bottom of the cabinet. For even
better cooling you can leave one unit above and one
under the amplifier blank.
The outlet air is blown out on the front panel.

2.5 MAINS Connection

The amplifier electronics of the standard European
model are set up for an AC line voltage of 230 volts,
50 or 60 Hz. Export versions with other voltages are
also available. If the power plug of the mains cable
should ever need to be replaced, ensure that the
connection to the protective earth is maintained.

2.6 MAINS Switch (POWER)

The mains switch is a 3-positon
rocker type. Shortly pushing the
upper end (ON) will power up the
P

RO

 A 2000. After a 5  second on

delay it will be ready and the mains
LED will light up. Pushing the lower
end (OFF) will interrupt mains

power. If a remote control module is present and set
in function, all amplifiers in a set can be powered on

!

Fig. 4 Mains switch

Содержание PRO A 2000

Страница 1: ...r Installation and Operation PRO A 2000 KLEIN HUMMEL GmbH Zeppelinstr 12 73760 Ostfildern Germany Tel 49 0 711 45893 0 Fax 49 0 711 45893 35 e Mail info klein hummel de Internet www klein hummel de 05...

Страница 2: ...e the breaks Avoid standing too close to loudspeakers that are being driven at high levels If you must be exposed to high sound pressure levels over an extended period of time use hearing protection M...

Страница 3: ...to audio sources 5 2 10 Output connectors 5 2 11 Expansion module slots 6 2 11 1 Controls and jumpers in the slots 6 3 Operation 6 3 1 Front panel 6 3 2 Indicators and level control 6 3 3 Diagnosis i...

Страница 4: ...e 2 2 Operating conditions The K H model PRO A 2000 high power amplifier is intended for use over a range of ambient temperatures from 10 C to 40 C 50 F to 104 F During transport or storage temperatur...

Страница 5: ...ne power and 1200 watts of peak power In some cases the protection circuit will reduce output power due to excessive temperature or load current Do not compress the audio signal and pay more and more...

Страница 6: ...leaving the factory the amplifier is set to maximum output power and long time constant Changing these settings makes only sense if the amplifier is always used together with the same speaker system...

Страница 7: ...n an optional audio module has been activated in slot 1 Audio Modul 2 on an optional audio module has been activated in slot 2 Audio Modul 3 on an optional audio module has been activated in slot 3 Lo...

Страница 8: ...is not terminated The input may not be terminated if several amplifiers are connected in a chain to one digital audio source by means of BNC T connectors However the coaxial cable has to be terminate...

Страница 9: ...t o n r o n i d e g g u l p e l u d o m n o i s n a p x e g n o r W w o l o o t s i d n u o S t c e r r o c t o n g n i t t e s r e t i m i L w o l n i a G n i d e g g u l p e l u d o m n o i s n a p...

Страница 10: ...DIM 100 85 dB 0 006 at rated output power into 4 Ohms Noise 120 dB unweighted at 26 dB gain and rated output power Damping 400 1 at 1 kHz and 4 Ohms Crosstalk 60 dB at rated output power into 4 Ohms 2...