5

Electrical Connection only for UK

WARNING!
This appliance must be earthed.

The manufacturers will not accept liability
for any problems however caused by the
failure of the user or installer to comply with
these instruction or with safety regulations.

It is recommended that installation is car-
ried out by a qualified electrician.

This appliance is intended to be perma-
nently connected to the electrical supply
trough a double-pole switched fused spur -
(disconnector) - fitted with a 3 or 5 amp fuse.
The opening distance between the switch
contacts shall not be less than 3 mm. The
installation must conform to the require-
ments of BS 7671.
The wires in the mains lead are coloured in
accordance with the following code:
Blue Neutral:
-To be connected to the supply terminal
marked ‘N’ or coloured Black.
Brown live:
-To be connected to the supply terminal
marked ‘L’ or coloured Red.
Yellow/Green earth:
-To be connected to the terminal marked
‘E’ or earth symbol or coloured  green.

This appliance is not intended to be con-
nected to the electrical supply through a
plug and socket, but if for any reason a plug
should be fitted, then it must be wired ac-
cording to the colour code as shown above.

Warning
Ensure that the appliance is isolated from
the supply before carrying out installation.

Fastening the hood to the wall

— Place the template against the wall. The

lower edge of the template must match
the lower edge of the hood (Fig. 5).

— Drill two Ø 8mm holes and two Ø 12mm

holes (Fig. 5).

— Fit the two Ø 8mm plugs in the top holes

(Fig. 5).

— Fasten the two hooks C in the bottom

holes (Fig. 5).

— Remove the grease filters (Fig. 10).
— Hang the hood on the hooks and level it

with the screws (Fig. 6).

— Secure it in place with the two 5x45 mm

screws and 5-20 mm diameter washers
in the top holes (Fig. 6).

— Refit the grease filter.

Installing the duct (exhaust version)
(Fig.  7)

— Fasten the top support E to the wall close

to the ceiling on the perpendicular of the
bottom connections. To do use the two
8mm diameter screws and plugs sup-
plied as standard equipment.

— Insert the plastic mould P on the duct.
— Take the measure h between the ceiling

and the hood top, and adjust the duct to
this height.
Fasten it with the screws F.

— Insert the duct with the slots downwards

and fasten it with the two top screws and
the two bottom screws G.

Installing the duct (filter version)

— Perform the same operations described

in the preceding paragraph.
With screws supplied, fasten the air con-
veyor M inside the duct (Fig. 8).

Fastening of shelves (optional)

Fasten the four side supports I to the adja-
cent cabinets and place the shelf on the
supports (Fig. 9).