![Kleenmaid OMFP6010 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/kleenmaid/omfp6010/omfp6010_service-manual_1976875007.webp)
Technical Overview
2.5
Oven Model Configuration
The manual test procedure must be completed and confirmed as per the instructions in this section.
At every POWER-UP, the control runs a latch auto-test cycle.
The lock icon flashes while the latch is
moving.
Keep the [MODE] knob to the 0 position
(see Figure 1)
.
1.
Hold [TEMP & TIME] knob for about 5 seconds until all the display elements turn on.
2.
Press[TEMP & TIME] and release the knob again, all the display elements turn OFF.
3.
Press [TEMP & TIME] the display shows the
“Configuration Model”
4.
Press [TEMP & TIME] the display shows the
“Software Version”
The model is set by connector (see picture 2) that must be placed in the same location
in case of control substitution.
Type
Num
ber
of
Func
tions
Mo
del
Configurat
ionModel
Software
Version
0
01
02
03
04
05
06
07
08
09
10
Therm
al
8
M
A0
1
00 5
Conve
ction
8
M
A0
2
n002
M
A0
3
Conve
ction
10
M
A0
5
n005
M
A0
6
Therm
al
5
M
A0
8
Figure 1