10
GAS SUPPLY:
■
The connection must be executed by an authorised person according to the rele-
vant standards.
■
Before connecting the appliance to the gas main, mount the brass conical adaptor
onto the gas inlet pipe, upon which the gasket has been placed (figures 9-10).
Conical adaptor and gasket are supplied with the appliance (packed with conver-
sion kit for use with Natural gas or Propane gas).
■
This appliance is suitable for use with Natural Gas or Propane gas. (Check the “gas
type” sticker attached to the appliance).
■
For Natural Gas models the gas supply is connected to the pressure regulator
which is supplied with the appliance (fig. 10). Adjust the regulator to obtain a test
point pressure of 1 kPa with the two semi-rapid (SR) burners operating at the maxi-
mum.
■
For Propane gas models the gas supply is connected to the test point adaptor
which is supplied with the appliance (fig. 9) and ensure that the supply pressure is
regulated to 2.75 kPa.
■
The connection must be made at the rear of appliance (left or right); the pipe do
not cross the cooker.
■
The inlet not used must be closed off with the cap and sealing gasket supplied.
■
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 12)
Gas connection for
PROPANE GAS
Figure 10
Figure 9
Gas connection for
NATURAL GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test point adaptor
Test
point
Test
point