GAS BURNERS
[
Check that the electricity is switched on to allow spark ignition.
[
Make sure that all controls are turned to zero.
[
The gas flow to the burner is controlled by a tap with safety valve device. If the burner
flame should go out for some reason, the safety valve will automatically stop the gas
flow. The switch of the electric ignition is incorporated in the knobs.
[
You control the flow by turning the knob indicator to line up with the following symbols:
B
Symbol : tap closed (burner off)
B
Symbol : High (maximum)
B
Symbol : Low (minimum)
[
To ignite automatically, simply push the required knob down and turn it to maximum,
keep the knob down until the burner lights. When the flame is lit, wait for about ten
seconds with the knob down (safety valve activation delay).
[
You can control the temperature by the knob from “high” to“low”.
[
To switch off, turn the knob clockwise until you hear the safety click.
[
Note that, if you are using a burner at the minimum setting, you turn the knob clockwise
past the maximum setting before reaching the off position.
[
If when lighting any of the burners an abnormal flame appears, switch that the burner
off and relight using the minimum setting.
[
If the flame is still different from normal, turn the burner off and consult your Kleenmaid
service agent.
[
In the case of an electric mains failure light the burner with a match or lighted taper.
USE OF COOKING HOB