background image

 

10 

 

 

INSTALLATION INSTRUCTIONS

 

 

 

 

VENTILATION OF ROOMS

 

 

The room in which this appliance is installed must be well ventilated by natural or mechanical means or 

a combination of both to ensure correct combustion and the removal of spent air. The minimum 

quantity of air for combustion will depend on the room volume, number of appliances and their total 

power rating. The power rating of your appliance can be found by reference to the Rating Plate.  

 

NOTE:

 The actual ventilation requirements must be determined by reference to the Statutory 

Regulations in force.  

 

GAS CONNECTION 

 

Data Label – The Data Label is located on the underside of the appliance. A duplicate label is supplied 

to adhere in an accessible area adjacent to the appliance. This appliance is suitable for Natural Gas 

and propane Gas; ensure that the available gas supply matches the Data Label. 

 

Test Point Pressure – The appliance is factory set for Natural gas. The test point pressure should be 

adjusted to 1.00 kPa with the relevant burners operating at maximum flame (see Table Page 7). 

 

Natural Gas – 1.00 kPa 

Propane Gas – 2.75kPa 

 

When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced 

with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.75 kPa should be part 

of the gas tank supply. Replace the old data plate with one, which is suitable for the type of gas for 

which the appliance has been regulated. 

 

The gas supply must be connected by use of the ½ BSP Elbow, Seal and copper pipe and an isolation 

tap fitted in an easily accessible position. For the location of the Gas Connection please refer to the 

following table:

 

 

MODEL 

Inlet Position 

Inlet (mm) 

from side 

Inlet (mm) 

from rear 

CH311XFF 

RHS Rear 

30 

30 

CH311WOKFF 

RHS Rear 

35 

30 

CH607X CH607W 

RHS Rear 

30 

30 

CH609X CH609W 

RHS Rear 

30 

30 

CH611XFF CH611WFF 

LHS Rear 

50 

40 

CH711XFF 

LHS Rear 

105 

40 

CH911XFF 

RHS Rear 

55 

40 

CH915XFF CH915AFF 

RHS Rear 

40 

40 

CH920XFF 

RHS Rear 

60 

45 

 

   

 

FIG 2 

 

The appliance as supplied is for use with Natural Gas, if it is to be adapted for LPG proceed as follows: 

  Isolate the appliance from the electricity and gas supplies. 

  Remove the pan supports and burner assemblies.  

  Replace the injectors with the alternative type supplied.  

  Use the appropriate thread sealant and check for gas soundness.  

  Affix the self-adhesive label to the Rating Plate to amend the Gas Category.  

Содержание CH311WOKFF

Страница 1: ...C o o k i n g C o o k i n g c o l l e c t i o n c o l l e c t i o n Instructions for Use and Warranty Details Gas Cooktops...

Страница 2: ...ions on how to install your new appliance Correct installation will avoid delays and unnecessary service calls Once installation is complete read this booklet carefully and get to know the controls an...

Страница 3: ...2 CONTENTS General Information Page 3 Warning and Safety Instructions Page 4 Instructions for Use Page 5 7 Installation Instructions Page 8 13 Technical Data Page 14 15 Conditions of Warranty Page 16...

Страница 4: ...new appliance is guaranteed against electrical or mechanical defects subject to certain exclusions noted in Kleenmaid Conditions of Warranty The foregoing does not affect your statutory rights In the...

Страница 5: ...e heating or to dry clothes Do not install the appliance next to curtains or soft furnishings DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIACE WHILE IT IS IN OPERATION WHERE THIS APPLIANCE IS IN...

Страница 6: ...failure auto ignition CH915AFF 6 burner including wok glass hob with aluminium control panel cast iron trivets with flame failure auto ignition CH920XFF 5 burner including wok stainless steel hob cas...

Страница 7: ...one that is the same or slightly larger than the flame ring The flame should never exceed the diameter of the pan The bottom of the pan should be flat and wherever possible keep the lid on the pan whe...

Страница 8: ...cloth dampened with hot detergent solution is sufficient but for stubborn marks the following is recommended Vitreous Enamel parts use only a cleaner that is recommended for this type of material Burn...

Страница 9: ...the hotplate Ventilation Ventilation must be in accordance with AS5601 AG601 installations In general the appliance should have adequate ventilation for complete combustion of gas proper flueing and...

Страница 10: ...the aperture and fix in position via the clamps screws tightening the screws evenly see Fig 1 below 6 Models CH311WOKFFand CH311XFF must be installed with the spacers that are attached to the undersi...

Страница 11: ...When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced with the Test Point Assembly A gas regulator suitable for a supply pressure of 2 75 kPa should be part...

Страница 12: ...sh in colour stable and noiseless and does not extinguish when changing from maximum to minimum flow Replace the control knob and check that all components have been reassembled correctly Before leavi...

Страница 13: ...ors Fig 3 with the corresponding type of gas to be used See table Page 15 To adjust to the minimum use a screwdriver on the screw placed on the tap Fig 4 after turning the tap to its minimum position...

Страница 14: ...minal marked E or the earth symbol or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Black The wire coloured Brown must be connected to...

Страница 15: ...t Lightly smear the cone with high temperature grease reassemble into position and rotate a few times Remove the cone again and remove any excess grease making sure that the gas ducts are not obstruct...

Страница 16: ...6 3 4 0 25 9 CH609X CH609W 14 4 6 3 4 0 31 0 CH611XFF CH611WFF 15 0 11 4 6 3 4 0 36 7 CH711XFF 15 0 11 4 6 3 4 0 43 0 CH911XFF 15 0 11 4 6 3 4 0 54 4 CH915XFF CH915AFF 15 0 11 4 6 3 4 0 54 4 CH920XFF...

Страница 17: ...f the above the Purchaser must pay for the cost of transporting the appliance to and from the Agent or the Agent s travelling cost to and from the Purchaser s home WHAT THESE WARRANTIES DO NOT COVER W...

Страница 18: ...ashers Ovens Cooktops Outdoor Cooking Centres Built In Coffee Machines Rangehoods Freestanding Ranges Sinks Waste Disposals Taps Cookware Refrigerators Freezers Wine Cellars Vacuum Cleaners For sales...