1. The system does not power on, begin the cleaning cycle, or the LED progress 
bar flashes when a disc is inserted.

Check that the 

power cord is connected between the unit and an AC wall 

outlet.

 

Confirm the voltage switch is properly set on the rear of the unit (See 

“Voltage Configuration”). 

Be sure the diameter of the LP record is between 

296-304 millimeters (11.65-12.00 inches); other sizes will not be detected. 

Make sure the “Completed” green LED light is illuminated before inserting a 
record. If not, try power cycling the unit (turning off/on using the front power 
switch), then removing and reinserting the disc.

3. Water is dripping from the unit.

The cleaning system must remain level at all times when filled with water. 
Check that the drain valve is closed (See “Draining and Maintenance”) and that 
the reservoir access cap is tightened shut (see “Accessing the Reservoir”).

4. The unit makes a loud noise during the auto priming or draining process.

Be sure there is sufficient water in the reservoir (See “Filling the Reservoir”).
If the reservoir is already full, unwanted debris may have entered the pump 
through the top loading slot. Completely drain and dry the unit (see “Draining & 
Maintenance”). Check inside the reservoir via the rear access cap. Significant 
debris or any hard particles should be removed before operation. Add new 
water after cleaning out the reservoir (see “Filling the Reservoir”).

5. The unit makes odd noises during the washing cycle (0-100%).

The ultrasonic transducers will produce a moderate squeeling or grinding 
noise when cleaning, which is normal. The record is also rotated with a belt 
motor during this process. If a more significant noise is heard, try turning off 
the unit and placing it onto a different surface. Although the transducers are 
insulated, vibrations might be exaggerated by some table surfaces.

6. The record does not rotate properly during the cleaning or drying cycle.

This can occur if there are significant irregularities or “flat spots” in the outer 
edge of the disc. It may help to lightly smooth the outer edge of the vinyl with 
sandpaper. If sanding, rinse the disc to remove vinyl debris before inserting it 
into the cleaning unit.

7. The power consumption of the unit is less than 200W.

Power consumption of the ultrasonic transducers depends upon the surface 
of the record. If there are less grooves or debris, power usage will be lower.

Troubleshooting

Limited Warranty

Disclaimer

Klaudio (“Klaudio”) warrants each new ultrasonic cleaning product against defects 
in materials or workmanship for a period of two years from the date of purchase, and 
agrees to repair or replace any defective Klaudio system without charge. Shipping 
costs are non-refundable.

This warranty is non-transferable. All warranty claims must be accompanied by the original 
proof of purchase.

THIS WARRANTY DOES NOT COVER DAMAGE RESULTING FROM ACCIDENT, MISUSE 
OR ABUSE, LACK OF REASONABLE CARE, SHIPPING DAMAGE, MODIFICATIONS, 
THE AFFIXING OF ANY ATTACHMENT NOT PROVIDED WITH THE PRODUCT, OR 
LOSS OF PARTS .

Use of chemical cleaning agents or liquids will void this warranty. Klaudio will not pay 
for warranty service performed by a non-authorized repair or diagnostic service and will 
not reimburse the consumer for damage resulting from warranty service performed by a 
non-authorized repair service. No responsibility is assumed for any special incidental or 
consequential damages due to a defective Klaudio product.

In order to obtain warranty service, contact our RMA department for information. The product 
must be shipped postage prepaid to an authorized Klaudio service location. It is suggested 
that, for your protection, you return shipments of product by insured mail, insurance prepaid. 
Damage occurring during shipment is not covered by this warranty. Shipping costs are non-
refundable. No other warranty, written or oral, is authorized by Klaudio.

IN NO EVENT SHALL KLAUDIO, PARENT COMPANY KOOLANCE, OR ITS EMPLOYEES, 
AGENTS, SUPPLIERS, MANUFACTURERS, OR CONTRACTORS BE LIABLE FOR 
ANY DAMAGES OF ANY KIND OR CHARACTER, INCLUDING WITHOUT LIMITATION 
ANY COMPENSATORY, INCIDENTAL, DIRECT, INDIRECT, SPECIAL, PUNITIVE, OR 
CONSEQUENTIAL DAMAGES, LOSS OF USE, LOSS OF DATA, LOSS OF INCOME OR 
PROFIT, LOSS OF OR DAMAGE TO PERSONS OR PROPERTY, CLAIMS OF THIRD 
PARTIES, OR OTHER LOSSES OF ANY KIND OR CHARACTER, AND WHETHER 
OR NOT THE POSSIBILITY OF SUCH LOSS OR DAMAGE HAS BEEN NOTIFIED TO 
KLAUDIO.

Содержание KD-CLN-LP200

Страница 1: ...English v1 1 www klaudio com Printed in Korea TM KD CLN LP200 Ultrasonic Vinyl Record Cleaner User s Manual TM...

Страница 2: ...a prohibited action ABOUT SIGNS Throughout this document critical information is highlighted in gray colored boxes The following symbols are intended to help prevent any situation which may cause pers...

Страница 3: ...r is added If the product is tilted water may spill onto and damage the electronics Do not tilt while filling Do not tilt while operating Keep unit level whenever water is inside Always drain water fr...

Страница 4: ...s 3 Setup 4 Voltage Configuration 5 Filling the Reservoir 5 Connecting the Power Cable 6 Adjusting Washing and Drying Settings 6 Understanding the LED Progress Bar 7 Operation 8 Loading a Record 9 Dra...

Страница 5: ...ogy allows powerful waves to remove debris without dam aging the disc and special dampening minimizes vibration and noise The entire washing and drying process can be adjusted from 3 to 9 minutes Clea...

Страница 6: ...incorrect setting can permanently damage the ultrasonic transducers This condition is not covered by the product warranty Filling the Reservoir Use only household tap water or distilled water to fill...

Страница 7: ...current drying progress based on the preset time Once finished the Completed green LED will illuminate The system will also emit an audio chime every few minutes until the disc has been removed Remove...

Страница 8: ...r to the floor The cleaning drying process will automatically start Once finished the Completed green LED will illuminate Insert a new disc to start again Draining and Maintenance It s recommended to...

Страница 9: ...knob on the side of the unit to Open Open Operation Accessing the Reservoir If necessary the reservoir can be accessed for cleaning or thorough drying Before opening the reservoir be sure it s complet...

Страница 10: ...g rinse the disc to remove vinyl debris before inserting it into the cleaning unit 7 The power consumption of the unit is less than 200W Power consumption of the ultrasonic transducers depends upon th...

Страница 11: ...14 This page has been intentionally left blank...

Отзывы: