69
Items to be checked
Possible malfunction
The gas valve and liquid valve of connection pipe are
open completely?
It may cause insufficient cooling (heating) capacity.
Test operation
1. Preparation of test operation
• The client approves the air conditioner installation.
• Specify the important notes for air conditioner to the client.
2. Method of test operation
• Put through the power, press ON/OFF button on the remote controller to start operation.
• Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check whether the operation is
normal or not.
•
If the ambient temperature is lower than 16℃, the air conditioner can’t start cooling.
Installation instructions of anti-collapse chain
• In order to prevent accidental collapse of indoor unit, please install the anti-collapse chain.
1. Remove the screw of anti-collapse hole at the top cover of indoor unit (see fig. 3).
2. Take out the anti-collapse chain and put it into the anti-collapse hole, and then tighten it with screw (see
fig. 4)
3. Fix the other end of anti-collapse chain on the wall with screw (ST4.2X38) (see fig. 4)
Fig. 3
Fig. 4
Put this end into the hole
and then tighten it with screw
Fix the other end on the wall with screw
Wall
Indoor unit
Remove the screw at the top cover
Anti-collapse hole