60
Air-conditioner
Air switch capacity
48 K
16 A
Installation of indoor unit
Step 1: recommend the installation location to the client and then confirm it with the client.
Step 2: opening pipe hole
1. Choose the position of piping hole according to the direction of outlet pipe.
2. Open a piping hole with the diameter of 70 mm on the selected outlet pipe position. In order to drain
smoothly, slant the piping hole on the wall slightly downward to the
outdoor side with the gradient of 5-10°.
Pay attention to dust prevention and take relevant safety measures
when opening the hole.
Step 3: outlet pipe
Indoor
5-10
outdoor
Φ70
1. The pipe can be led out in the
direction of left, right or rear.
2. After confirming the direction of outlet pipe,
direction of left, right or rear. loosen the screws
at the upper and lower adjusting baffle to let the
connection pipe /drain pipe connects the indoor
unit.
Step 4: Connect the pipe of indoor unit
1. Take out the left and right screw cover and then
remove the screws on air-inlet panel to remove
the panel.
left
left
back
back
right
right
upper and lower adjusting baffle
air-inlet panel
screw