background image

Female XLR

Male XLR

Pin 1 - Screen/Ground
Pin 2 - Hot Signal
Pin 3 - Cold Signal

Pin 1 - Screen/Ground
Pin 2 - Hot Signal
Pin 3 - Cold Signal

Note: XLR Sockets are viewed from the
front face.

Phoenix Type Connector

Pin 1 - Channel IN Screen/Ground
Pin2 - Channel IN Hot Signal
Pin 3 - Channel IN Cold Signal
Pin 4 - Channel OUT Screen/Ground
Pin 5 - Channel OUT Hot Signal
Pin 6 - Channel OUT Cold Signal

Note: Pin assignments as viewed from the
socket. Phoenix connector is wired in parallel with
the corresponding XLR.

The following special limitations must be observed in order to maintain safety and electromagnetic compatibility
performance.

Power Connection

The DN370 Graphic Equaliser should only be operated with the
power supply connected to ground via the ground in the mains
connector.

Audio Connections

The DN370 should only be operated with high quality twisted-
pair audio cables. XLR connector shells should be of metal
construction so that they provide a screen when connected to
the console and should have pin one (1) connected to the cable
screen.

Electric Fields

If the DN370 is operated in an electromagnetic field that is
amplitude modulated by an audio frequency signal, the signal
to noise ratio may be degraded. Degradation of up to 60dB
may be experienced under extreme conditions (3V/m, 90%
modulation).

INSTALLATION

Position

Power

The DN370 should be mounted in a nineteen inch (19”) rack of suitable construction for it’s intended purpose. Four (4) rack
mount holes are provided through the front panel to support fully, the weight of the unit in the rack. Position of the unit will
depend upon how it is to be used however:-

- Avoid placing the unit such that the faders may be accidentally knocked or snapped off
- Avoid placing the unit such that the front mounted power switch may be accidentally knocked

Also try to avoid placing the unit directly near or on any power distribution units or power amplifiers.

The internal power supply is a switch mode type which automatically senses the incoming mains voltage and will work where the
nominal voltage is in the range 100-240 VAC. A single fused IEC mains inlet is provided on the rear panel and the correct lead for
connection in the area to which the unit was shipped is provided in the box.

Connections

After Unpacking

To ensure the correct and reliable operation or your DN370 Graphic Equaliser, only high quality balanced screened twisted pair
audio cable should be used.

After unpacking your DN370, please retain the original packing in the event that you should need to transport or ship the unit.
Please inspect the unit carefully for any signs of damage that may have occurred in transit and notify the courier immediately if
you feel that any damage has occurred.

1

2

3

1

2

3

1

2

3

4

5

6

ATTENTION

DN

Operators Manual -

370

Page 2

Содержание DN370

Страница 1: ...ik Group Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 0 1562 741515 Fax 44 0 1562 745371 Email sales ktgplc com Website www klarkteknik com OPERATORS MAN...

Страница 2: ......

Страница 3: ...the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade...

Страница 4: ......

Страница 5: ...r or user is drawn to special limitations of use which must be observed when these products are taken into service to maintain compliance with the above directives Details of these special measures an...

Страница 6: ......

Страница 7: ...presents the next generation of graphic equaliser technology All backed up of course by the standard Klark Teknik three year warranty Please take the time to complete and return the registration card...

Страница 8: ...odulation INSTALLATION Position Power The DN370 should be mounted in a nineteen inch 19 rack of suitable construction for it s intended purpose Four 4 rack mount holes are provided through the front p...

Страница 9: ...dB Level metering High and low pass filters per channel Notch filters per channel Power switch a n d p o w e r indicator E q u a l i s e r i n o u t switch to bypass the effect of the equaliser Channe...

Страница 10: ...DE M ME TYPE COMME INDIQU CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE T...

Страница 11: ...h is in the OUT position but control over the channel LEDs is retained by the gain control Although range is discussed above a description is included here for clarity The range of the graphic equalis...

Страница 12: ...ow Pass Filter and two 2 variable frequency Notch filters Each filter can be enabled by depressing the pot until it clicks only a small amount of force is required When active the annular ring around...

Страница 13: ...250A SUPPLY VOLTAGE OUTPUT B INPUT B PUSH INPUT TX OUTPUT TX Channel Input XLR Channel Input Output Phoenix Connector Channel Output XLR Indicates whether the transformer isolation input and output op...

Страница 14: ...DN Operators Manual 370 Page 8...

Страница 15: ...EQUALISER EQUALISER X Over Amplifiers X Over Amplifiers X Over Amplifiers X Over Amplifiers Delay FoH Delay FoH Centre Cluster Main FOH Main FOH Stage Monitors Monitor Console Example System connectio...

Страница 16: ...forming bass enclosures will use up large amounts of system headroom which could cause the system amplifiers to clip Causing damage to loudspeaker HF components and introducing high frequency harmonic...

Страница 17: ...and similarly the deficient bands are increased You will need to perform the test at a reasonable level approaching normal usage volume so that the equalisation can take into account the response of t...

Страница 18: ...requency 31 40 50 63 Fundamentals of bass drum tuba bass and organ These give music a sense of power but excessive use can leave the sound muddy Mains Hum 50 60Hz 80 100 125 Too much boost produces bo...

Страница 19: ...REQUENCY PUSH BYPASS PUSH BYPASS PUSH BYPASS PUSH BYPASS BYPASS 40dBu 22dBu TRANSFORMER OPTION TRANSFORMER OPTION REMOVE LINK FOR TX OPTION REMOVE LINK FOR TX OPTION DN370 SINGLE CHANNEL FUNCTIONAL BL...

Страница 20: ...ent EQ bands alters the frequency response Lower Q filters will blend together more smoothly but higher Q filters provide more selective control of problems at the expense of more frequency response r...

Страница 21: ...sation is that the EQ bands are wider at lower amounts of boost and cut and become narrower as greater amounts are applied giving the optimum balance of smoothness and accuracy over the entire fader t...

Страница 22: ...e and therefore allowing higher SPLs to be used The two notch filters further enhance the unit s ability to precisely tune out problem frequencies The response of the notch filters was selected after...

Страница 23: ...indication The design of the all new graphic filters with carefully selected proportional Q responses ensures that problem frequencies can be attenuated quickly and effectively Long throw faders allo...

Страница 24: ...ilters allows unparalleled precise control of frequency response The examples adjacent show how the filters can be used on their own and in conjunction with the graphic equaliser to handle problems en...

Страница 25: ...the Symmetrical Q equaliser affects a broader range of frequencies than using the Proportional Q response of the DN370 s faders The ability to overlap the notch filters both with each other and with t...

Страница 26: ...DN Operators Manual 370 Page 20...

Страница 27: ...High Pass Filter Slope 12 dB octave Low Pass Filter Slope 12 dB octave Notch filter Attenuation 18dB Q 32 Audio 3 pin XLR and 6 pin Phoenix Power 3 pin IEC Voltage 100V 240V a c Consumption 60W Heigh...

Страница 28: ...ICCOLO FLUTE OBOE BASSOON TRUMPET TROMBONE TUBA SOPRANO CONTRALTO BARITONE BASS PEJ MMIV Note The above information is provided as a rough guide to the range of fundamental frequencies used by various...

Страница 29: ...SER 6 12 12 6 12 12 6 6 DN370 DUAL GRAPHIC EQUALISER DN370 DUAL GRAPHIC EQUALISER Location Application Date DN370 DUAL GRAPHIC EQUALISER 6 12 12 6 12 12 6 6 Location Application Date Crib sheet DN Ope...

Страница 30: ...y 2004 DOC02 DN370 c Klark Teknik Group UK PLC In line with the company s policy of continual improvement specifications and function may be subject to change without notice The contents of this Opera...