18
Installation
Note:
The safety distance between the hotplate and the
cupboard above
the hotplate should be at least 760mm.
Under any circumstances, make sure the ceramic cooker hob is well
ventilated and the air inlet and outlet are not blocked. Ensure the
ceramic cooker hob is in good work state. As shown below
Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the pa-
ckaging). Do not apply force onto the controls protruding from the hob.
Fix the hob on the work surface by screw four brackets on the bottom
of hob (see picture) after installation.
!
A(mm)
B(mm)
C(mm)
D
E
760
50 min.
30 min.
Air intake
Air exit 10 mm