44
Installation
SEAL
+4
+1
+4
+1
Note:
The safety distance between the hotplate and the
cupboard above
the hotplate should be at least
760mm
.
Under any circumstances, make sure the ceramic cooker hob is
well ventilated and the air inlet and outlet are not blocked. Ensu-
re the ceramic cooker hob is in good work state. As shown below:
•
The counter top is flat and horizontal and nothing extends into the work
-
space.
• The base (counter top) consists of a heat-resistant material.
• If installed above an oven, the oven must have its own fan.
• The installation must comply with all standard operation procedures and
and other regulations.
• A separate and suitable fuse must protect the circuit and comply with
local regulations.
• This fuse must be tested and have at least 3 mm of ambiance around all
poles (or all active [phase] conductors if provided for in the regulations).
• The fuse must be easily accessible to the installer.
• Contact a specialist or the building control authority if you are not sure
about the installation.
!