See KKDC website for product document updates.
www.kkdc.lighting
CV035125WG-02.01EN-20190617
High Power
Note: This guide is produced from testing with KKDC approved power supplies or control gear.
Performance with other power or control products cannot be guaranteed. Contact KKDC for further information.
KKDC may change product specifications and installation guidance without prior notice.
READ BEFORE INSTALLATION
• Cables used for connecting KKDC products must be of a suitable type and recommended gauge. Cable insulation must remain
undamaged and conductors free from dirt and corrosion.
• Control cables should be of a suitable shielded type and not fixed in proximity to high voltage power cables or other sources of
electromagnetic interference.
• When connecting KKDC products always observe the correct polarity (+/-). Failure to do so may destroy the product.
• Electrical circuits should be wired with power off and all wiring and connections should be complete and checked thoroughly
before power is switched on. Take particular care not to confuse any control and power wiring. Do not remove any supplied
product cable labels.
• Power supplies should not be made ‘live’ without the correct load attached and the low voltage output must not be switched.
Do not exceed the recommended load.
• Remove only the minimum of cable insulation necessary to make wiring connections to eliminate the possibility of short circuit.
• Cables should be joined with terminal blocks and adequately protected against water immersion or moisture ingress with suitable
tapes and sealants, potting compounds and IP rated junction boxes as appropriate to the installation and operating environment.
• The LED products in this guide require
24V DC
(constant voltage) Class 2 power supplies (UL listed – for North America).
• When connecting
CV 035
products end to end –
Do not exceed 2m/6.56 ft
(from any one parallel power feed – see wiring examples).
WIRING EXAMPLES
Switched
Cable size / Max distance (d)
0.5mm²/
20AWG
0.75mm²/
18AWG
1.0mm²/
17AWG
1.5mm²/
15AWG
2.5mm²/
13AWG
SEN CV 035
(1.5m/4.9ft) + 125W PSU
8m/26ft
12m/39.4ft
16m/52.5ft
24m/78.7ft
40m/131.2ft
24V DC
125W
+ red
- black
Max distance (d)
1.5m/4.9ft max
1.5m/4.9ft max
1-10V Dimming
Cable size / Max distance (d)
0.5mm²/
20AWG
0.75mm²/
18AWG
1.0mm²/
17AWG
1.5mm²/
15AWG
2.5mm²/
13AWG
SEN CV 035
(1.5m/4.9ft) + 125W PSU + visDIM 1-10V
5m/16ft
9m/29.5ft
12.5m/41ft
20m/65.6ft
34.5m/113.2ft
24V DC
125W
Max 2m/6.6ft
+ red
- black
Max distance (d)
1.5m/4.9ft max
1.5m/4.9ft max
(max 50m/164ft @ 22 AWG)
visDIM
1-10V
1-10V
Control
DMX/DALI Dimming
Cable size / Max distance (d)
0.5mm²/
20AWG
0.75mm²/
18AWG
1.0mm²/
17AWG
1.5mm²/
15AWG
2.5mm²/
13AWG
SEN CV 035
(1.5m/4.9ft) + 125W PSU + visDIM DMX/DALI
5m/16ft
8.5m/22.9ft
12m/39.4ft
19m/62.3ft
33m/108.3ft
24V DC
125W
Max 2m/6.6ft
+ red
- black
Max distance (d)
1.5m/4.9ft max
1.5m/4.9ft max
Control
visDIM
(max 50m/164ft @ 22 AWG)
visDIM DMX
visDIM DALI
CV 035 + 125W PSU
Installation Guide – Wiring