19
NOTES:
Always unplug the breast pump from the power supply after use.
Do not fill the collection container beyond the marking.
Be careful not to pinch the tubes during use.
d)
After each use
➊
Disconnect the breast shield tube(s) and unscrew the breast shield(s) from the collection container(s).
➋
Secure the cap(s) onto the collection container(s)
➌
Disconnect the tube(s) from the interface bottle. Check that no milk has penetrated into the interface
bottle or inside the tubes.
➍
After each use, rinse and clean every part as described in chapter 3.
➎
Store the breast pump and its accessories in a dry place away from sunlight.
5.
Breastfeeding
a)
Storing breast milk
Information on the preservation of breast milk is available on the website
KOLORYOU®.
b)
Baby’s breastfeeding physiology
The FISIO® PRO breast pump provides mothers with the natural sensation of breastfeeding by recreating the
way in which the baby feeds.
It reproduces the 2 physiological phases of the breastfeeding:
- The stimulation phase to generate the milk let-down (short, rapid movements),
- The expression phase to collect milk (longer, less frequent movements).
6.
Safety precautions
Use of electricity
Before connecting the breast pump to the power supply, check the values on the breast pump (Volt –V-
and Hertz –Hz-) with your distribution network.
The warranty does not cover faulty connections.
This medical device is designed to operate at altitudes less than or equal to 3 000 meters.
Do not open the breast pump when connected to the power supply.
Warning: this medical device is directly connected to the electric power supply, do not use it in bath or
under the shower, do not immerse.
Keep this medical device away from any high heat source.
Connect the breast pump to an easy-to-access socket to allow quick disconnection of the network in the
event of a problem.
The plug is the disconnection device and must always be accessible.
Use of breast pump
The user of this medical device is the breastfeeding mother.
This medical device must not be left within the reach of unsupervised children or animals (potential
hazards with tubing and detachable components, risk of electrification).
The breast pump should be installed and started up in accordance with the information supplied in the
accompanying documents.
Properly store the breast pump and its accessories after use.
An animal may gnaw at the power cord. Be sure to check the condition of the equipment before use.
Do not use the appliance outdoors, near a heat source or near a water source (bathtub, sink ...).
Make sure the unit is not exposed to direct sunlight or excessive heat.
This medical device must not be used in presence of a mixture of inflammable anaesthetic with air or
oxygen or nitrous oxide.
After use, unplug the appliance from the wall outlet.
Fragile medical device, to be handled with care.
Содержание FISIO PRO
Страница 61: ...61 21 93 42 CEE 14 1993 II 3 2 5 0 BF Off I On 13 2005 BPA...
Страница 65: ...65 6 V Hz 3000 KIT EXPRESSION 43 5 10 KOLOR 7 DTF MEDICAL DTF MEDICAL...
Страница 66: ...66 KOLOR KIT EXPRESSION KIT EXPRESSION c 1 9 1 120 I O d 3 5 a www dtf fr KOLORYOU b FISIO PRO...
Страница 67: ...67 c KOLOR 10 1000 d KIT EXPRESSION KOLOR 125 30 134 18 50 4 a FISIO PRO b DTF MEDICAL KIT EXPRESSION 3...
Страница 68: ...68 4 4 2 S 76 L 90 KITETT araroKoK KOLORYOUR 2 S L 3 a b KOLOR 20 10 10...