4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
Parts Supplied
Check that all parts are included.
■
LP/Natural Gas Conversion Kit
■
10-32 hex nuts (attached to terminal block) (3)
■
Direct wire lugs (3)
■
#10 x 1
⁵⁄₈
" (4.1 cm) screws (for mounting anti-tip bracket) (2)
■
Anti-tip bracket (inside oven cavity)
Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to
anchor bracket to subfloor. Longer screws are available from
your local hardware store.
■
For Models:
Parts Needed
If using a power supply cord kit:
■
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1
³⁄₈
" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
■
A UL listed strain relief.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the appropriate “Electrical
Requirements” and “Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Optional Parts
To purchase these or any other accessories, please reference the
“Accessories” section of the User Guide for contact information.
■
Side Trim Kits:
⁵⁄₈
" (1.7 cm) White - Order Part Number W10675027
⁵⁄₈
" (1.7 cm) Black - Order Part Number W10675026
⁵⁄₈
" (1.7 cm) Stainless Steel - Order Part Number W10675028
1
¹⁄₈
" (2.9 cm) White - Order Part Number W10731885
1
¹⁄₈
" (2.9 cm) Black - Order Part Number W10731886
1
¹⁄₈
" (2.9 cm) Stainless Steel - Order Part Number
W10731887
■
Backsplash Kits:
High 6" (15.2 cm) White - Order Part Number W10655448
High 6" (15.2 cm) Black - Order Part Number W10655449
High 6" (15.2 cm) Stainless Steel - Order Part Number
W10655450
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the oven door on
the top right-hand side of the oven frame.
■
The range should be located for convenient use in the
kitchen.
■
Recessed installations must provide complete enclosure of
the sides and rear of the range.
■
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood or microwave hood combination that projects
horizontally a minimum of 5" (12.7 cm) beyond the bottom of
the cabinets.
■
All openings in the wall or floor where range is to be installed
must be sealed.
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■
Tape measure
■
Phillips screwdriver
■
Flat-blade screwdriver
■
¹⁄₈
" (3 mm) flat-blade
screwdriver
■
Level
■
Drill
■
Wrench or pliers
■
Pipe wrench
■
¹⁵⁄₁₆
" (2.4 cm) combination
wrench
■
¹⁄₈
" (3.2 mm) drill bit (for
wood floors)
■
Marker or pencil
■
Pipe-joint compound
resistant to LP gas
■
³⁄₁₆
" (4.8 mm) carbide-tipped
masonry drill bit (for
concrete/ceramic floors)
■
Noncorrosive leak-detection
solution
For LP/Natural Gas
Conversions
■
½" (13 mm) combination
wrench
■
¼" (6 mm) nut driver
■
⁹⁄₃₂
" (7 mm) nut driver
■
Masking tape
KSDB900E
YKSDB900E
JDS1450CD
JDS1450D
Burner Caps
5
4
Burner Grates
2
3
Oven Racks
3
3