23
3.
Unscrew the metal cover and unscrew the blue regulator
cap. Keep the washer in place.
4.
Flip the blue regulator cap over and screw it back into the
metal cover.
5.
Screw the metal cover securely back into place. Do not
overtighten.
To Convert Surface Burners (Natural Gas to Propane
Gas)
1.
If installed, remove the burner grates.
2.
Remove the burner caps.
3.
Remove the burner base.
D
A
B
C
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
4.
Apply masking tape to the end of a
9
/
32
" (7 mm) nut driver to
help hold the gas orifice spud in the nut driver while
changing it. Press nut driver down onto the gas orifice spud
and remove by turning it counterclockwise and lifting out.
Set gas orifice spud aside.
5.
Remove the orifice spuds shipped in the literature package
in the oven. Gas orifice spuds are stamped with a number,
marked with 1 or 2 color dots, and have a groove in the hex
area. Replace the Natural gas orifice spud with the correct
Propane gas orifice spud.
Refer to the following chart for correct Propane gas orifice
spud ratings and to spud holder card for proper placement.
Fully insert choke into bottom of x-large burner base. Choke
should snap into place.
NOTE:
Use only for spreader bases marked “XL.”
Propane Gas Orifice Spud Chart for Surface Burners
*Not in all kits/models.
NOTE:
Refer to the model/serial/rating plate located on the oven
frame behind the top right-hand side of the oven door for proper
sizing of spuds for each burner location.
6.
Place Natural gas orifice spuds in the orifice spud bag.
IMPORTANT:
Keep the Natural gas orifice spuds in case of
reinstallation with Natural gas.
7.
Replace the burner base.
8.
Replace burner cap.
9.
Repeat steps 1 to 7 for the remaining burners.
10.
Replace the baking drawer. See the “Remove/Replace
Drawer” section.
A
B
C
D
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
A
A. Propane groove
Burner Rating/
Type
Color
Size
(mm)
ID
Number
Placement
15,000 BTU/
Stacked*
Silver
Black/Orange
1.05
0.32
L105
L32
LF
14,200 BTU/
Ultra/Stacked*
Silver
1.05
L105
LF/RF
8,000 BTU/
Semi
Red/Orange
0.85
L85
RR/CTR
5,000 BTU/
Auxi
Red/Blue
0.65
L65
LR
1,200 BTU/
Stacked/
Simmer*
Black/Orange 0.32
L32
LF
(Simmer)
A. Metal cover
B. Washer
C. Blue regulator cap
A
B
A
C
A. Natural gas position
B. LP gas position
A
B
A
B
C
X-Large Burner
A. Burner cap
B. Burner base
C. Gas tube opening
D. Choke (for use with x-large burner, Propane gas only)