6-2
TROUBLESHOOTING CHART
P roblem
P robable C aus e
T es t P roc edure-Ac tion
No power at wall outlet
C heck circuit
breaker/fus es
No power at
auxilary drain
pump power outlet
C heck for kinked drain
hos e, blocked s creen or
blocked vent outlet or
hos e.
Disconnected
s elector s witch
Reconnect and check for
proper operation.
Loos e connections
at s elector s witch
or control board
R epair connections
No power through
power cord
C heck continuity of power
cord and replace if open
R oom temperature
below 55
°
F (13
°
C )
B in thermis tor has unit
s hut off C us tomer
Ins truction
Ice touching bin
thermis tor
Normal operation
W ater s upply turned
off
T urn on water s upply
Loos e or mis s ing
res ervoir cap
T ighten or replace
W ater s lide return tube
out of res ervoir
R epos ition tube
Inlet tube out of
pos ition and mis s ing
res ervoir
R epos ition tube
W ater inlet tube frozen
near evaporator
T haw and repos ition tube
Defective inlet water
valve
T es t and repair or replace
An ice s lab only
partially releas ed from
evaporator and water
was bridged down into
the bin
Look for interference with
cutter grid and clean the
evaporator plate (s ee
procedure on page 8-1)
W ill not make ice
W ater res ervoir is
empty
E vaporator is cold
with thin or no ice
s lab
W ill not run
Содержание Kitchen Aid KAR-19
Страница 57: ...6 5 DIAGNOSTIC FLOW CHARTS FOR ICE MAKER CONTROL BOARD OVERVIEW ...
Страница 61: ...6 9 Harvest Bin Not Full ...
Страница 62: ...6 10 Harvest Bin Full ...
Страница 66: ...6 14 NOTES ...
Страница 67: ...7 1 WIRING DIAGRAM STRIP CIRCUITS WIRING DIAGRAM MEASURED FILL WATER VALVE ...
Страница 70: ...7 4 NOTES ...
Страница 74: ......