3.
Remove foam strip from literature packing. Remove backing
from foam strip. Apply foam strip adhesive-side down along
the left and right sides of the cooktop trim.
NOTE:
The foam strip helps the cooktop sit flat on uneven
counters and avoids damage to the countertop surface.
4.
Using 2 or more people, turn cooktop right-side up.
Install Optional Backguard
48" (121.9 cm) models and all models with a grill may require
a backguard. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements. See
the “Tools and Parts” section for information on ordering.
Remove island trim and attach backguard using 6 screws;
insert 3 from the front and 3 from the back (9" [22.9 cm]
backguard shown).
Make Gas Connection
To Assemble Pressure Regulator:
1.
Using 2 or more people, stand the cooktop on its side
or back.
2.
Connect the flexible stainless steel connector to the pressure
regulator using a
1
/
2
" male pipe thread adapter.
A combination of pipe fittings must be used to connect the
cooktop to the existing gas line. Shown following is a typical
connection. Your connection may be different, according to
the supply line type, size, and location.
A
B
C
A. Cooktop base
B. Foam strip
C. Cooktop
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
D
C
A. Gas pressure regulator
B. Regulator - Must be installed with arrow pointing up
to cooktop bottom.
C. Adapter - Must have
1
/
2
" male pipe thread.
D. CSA Approved flexible stainless steel gas supply line