13
Complete Connection
1.
Check that the gas pressure regulator shutoff valve is in the
“on” position.
A. Gas pressure regulator shut-off valve shown in the “on”
position
2.
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3.
Test
all
connections
by
brushing
on
an
approved
noncorrosive
leak-detection
solution.
If
bubbles
appear,
a
leak
is
indicated.
Correct
any
leak
found.
4.
Remove
cooktop
burner
caps
and
bases
from
package
containing
parts.
Place
the
burner
bases
as
indicated
by
the
following
illustration
for
your
model:
For
Oval burner
models
:
A.
Medium
(Semi
Rapid)
B.
Large
(Ultra
Rapid)
C.
Oval
D. Small (Auxiliary)
E. Large (Ultra Rapid)
For
Round burner
models:
A. Medium
(Semi Rapid)
B. Large
(Ultra Rapid)
C. Medium
(Semi Rapid)
D. Small (Auxiliary)
E. Large (Ultra Rapid)
5.
Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
A. Burner base
B. Burner cap
C. Burner grate