KitchenAid KEBS107SSS04 Скачать руководство пользователя страница 5

5

F6
Systems
(continued)

E1

Cook oven over 
temperature

E2

Clean oven over 
temperature

SUGGESTED CORRECTIVE ACTION PROCEDURE

PROCEDURE: Before proceeding, perform steps 1 through 3 of “To 
Enter Diagnostics Mode.”
1.

If oven is off, turn oven on and inspect all of the elements, convect 
ring, bake and broil. Visually inspect all elements to ensure they are 
not operating.

2.

Unplug oven or disconnect power. Wait 10 seconds.

3.

Plug in oven or reconnect power.

4.

Enter into Diagnostics mode by pressing OFF > OFF > START. 

5.

Press the BAKE key to cycle the Bake relay on and off as long as 
Diagnostics mode is within the first 120 seconds of powering up.
If the Bake relay does not cycle on and off, go to Step 6.

If the element does not cycle with the relay, go to Step 11.

If the element does cycle on and off, go to Step 9.

6.

Unplug oven or disconnect power for 30 seconds.

7.

Plug in oven or reconnect power.

8.

Enter the diagnostics mode described in steps 1 through 3 of “To 
Enter Diagnostics Mode.” Press the BAKE key and cycle relay on 
and off.
If the Bake relay does not cycle on and off, go to Step 13.

If the element does not cycle with the relay, go to Step 11.

If the element does cycle on and off, go to Step 9.

9.

Enter the diagnostics mode described in steps 1 through 3 of “To 
Enter Diagnostics Mode.” Press the BROIL key to cycle the Broil 
relays. Ensure outer broil relay energizes by inspecting the outer broil 
element. Press BROIL key again for inner broil element. Ensure inner 
broil relay energizes by inspecting the inner broil element.
If the Broil relay does not turn on and off, go to Step 13.

If the element does not cycle with the relay, go to Step 11.

If the element or gas valve did cycle on and off, go to Step 10.

10. Enter the diagnostics mode described in steps 1 through 3 of “To 

Enter Diagnostics Mode.” Press the CONVECT BAKE key to cycle 
the convect bake relay on and off.
If the Convect Bake relay does not turn on and off, go to Step 13.

If the element does not cycle with the relay, go to Step 11.

If the element did cycle on and off, go to Step 11.

11. Unplug oven or disconnect power.
12. Check integrity of all harness wires and connections between the 

appliance manager and the electric elements. Ensure all wiring and 
connections between the appliance manager and elements, and the 
appliance manager and user interface are intact and properly seated 
and that no wires are shorted or damaged

If the wiring connections are not intact, go to Step 17.
If the wiring is good, go to Step 14.

13. Unplug oven or disconnect power.
14. Replace the appliance manager. Go to Step 16.
15. Unplug oven or disconnect power.
16. Replace the user interface board. Go to Step 17.
17. Replace the harness. 
18. Replace all parts and panels before operating.
19. Plug in oven or reconnect power.
20. Verify operation is normal. Enter into Diagnostics mode by pressing 

OFF > OFF > START and complete checks.

F6
Systems
(continued)

E3

Mini oven/warm drawer 
over temperature

SUGGESTED CORRECTIVE ACTION PROCEDURE

PROCEDURE: Oven is not equipped with this feature. If error occurs, 
before proceeding press OFF, OFF, START to enter into Diagnostics 
mode and verify the error codes. If error code returns, replace user 
interface with correct control associated with this product.

FAILURE (Leftmost
2 Clock Digits)

ERROR (Rightmost
2 Clock Digits)

LIKELY FAILURE 
CONDITION

F6
Systems
(continued)

E4

User interface/
appliance manager 
mismatch

SUGGESTED CORRECTIVE ACTION PROCEDURE

PROCEDURE: Before proceeding, perform steps 1 through 3 of “To 
Enter Diagnostics Mode.”
1.

Unplug oven or disconnect power. Wait 10 seconds.

2.

Plug in oven or reconnect power.

3.

Enter into Diagnostics mode by pressing OFF > OFF > START.

4.

Press BAKE. Ensure Bake relay energizes by inspecting Bake 
element.

5.

Press BROIL 1 time for outer broil element. Ensure Outer Broil relay 
energizes by inspecting the Outer Broil element.

6.

Press BROIL again for Inner Broil element. Ensure Inner Broil relay 
energizes by inspecting the Inner Broil element.

7.

Press SELF CLEAN to drive door latch to lock door. Press again to 
reset door latch to normal state.

8.

Press COOK to activate the low speed cooling fan. Press again for 
high speed.

9.

If all functions do not work properly, go to Step 13.

10. If all functions are working, the Appliance Manager and User 

Interface are working properly.

11. Exit Diagnostics by pressing OFF.
12. Press BAKE and ensure that the Bake relay energizes and the control 

enters the Bake Preheat. Wait up to 60 seconds to ensure error has 
been resolved. If error returns, proceed to Step 13.

13. Unplug oven or disconnect power.
14. Remove covers for access to oven controls.
15. Replace the appliance manager. Ensure all connections are properly 

seated.

16. Replace all parts and panels before operating.
17. Plug in oven or reconnect power.
18. Press BAKE and ensure that Bake relay energizes and the control 

enters into Bake/Preheat. Wait up to 60 seconds to ensure error has 
been resolved. If error returns, go to Step 19.

19. Unplug oven or disconnect power.
20. Replace the user interface. Ensure all connections are properly 

seated. Go to Step 21.

21. Replace all parts and panels before operating.
22. Plug in oven or reconnect power.
23. Press BAKE and ensure the Bake relay energizes and the control 

enters into Bake/Preheat. Wait up to 60 seconds to ensure error has 
been resolved.

24. Verify operation is normal. Enter into Diagnostics mode by pressing 

OFF > OFF > START and complete checks.

F6
Systems
(continued)

E5

No cavity size 
command

SUGGESTED CORRECTIVE ACTION PROCEDURE

PROCEDURE: Before proceeding, perform steps 1 through 3 of “To 
Enter Diagnostics Mode.” Control should immediately power up in Cavity 
Size Select mode. Using key “6” (DOWN) and key “3” (UP) scroll through 
to locate the corresponding cavity size.
Once located press the START key to accept the proper cavity size for 
the oven being programmed. Control should reinitialize to cavity size 
selected. If error returns at least 60 seconds after cavity size has been 
set, go to Step 1.
1.

Unplug oven or disconnect power. Wait 10 seconds.

2.

Plug in oven or reconnect power.

3.

Enter into Diagnostics mode by pressing OFF > OFF > START. Press 
“6” (DOWN) once main diagnostic screen appears. Screen should 
identify cavity size for oven being programmed. If this is incorrectly 
shown, press CLOCK to edit current programmed size. Press “6” 
(DOWN) to locate proper cavity size. Once located, press START to 
accept the new cavity size. Control will reset and initialize the new 
cavity size programmed. Wait for 60 seconds to ensure error has 
been corrected.

4.

If error is corrected, go to Step 8.

5.

If error returns, go to Step 6.

6.

Unplug oven or disconnect power.

7.

Replace user interface ensuring all connections are properly seated 
and go to Step 8.

8.

Replace all parts and panels before operating.

9.

Plug in oven or reconnect power.

10. Control may power up in Cavity Size Select mode. Set cavity size as 

outlined in Step 3 by locating proper cavity size and pressing START 
once located. Wait for 60 seconds to ensure error has been 
corrected.

11. Verify operation is normal. Go to Step 1 of “To Enter Diagnostic 

Mode” and complete checks.

FAILURE (Leftmost
2 Clock Digits)

ERROR (Rightmost
2 Clock Digits)

LIKELY FAILURE 
CONDITION

Содержание KEBS107SSS04

Страница 1: ...ess the START key to accept modification Tech Sheet Do not discard WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Software copyrighted This product is covered by one or more of the following patents U S Patent Nos 4 852 544 4 974 804 5 008 516 5 064 998 5 138 137 5 142 125 5 17...

Страница 2: ...t press CLOCK key 7 Press START key to clear last error Control should display GOOD Troubleshooting Key strokes Press the Bake key to activate Bake relay Press Broil key once to activate Outer Broil press again for Inner Broil Press Convect Bake key to activate Convect Ring and Fan Press Self Clean key to activate Latch Motor Press Cook time key once to activate low speed press again for high spee...

Страница 3: ...ect the wires between P2 on the appliance manager and the indicated temperature sensor Make sure the wires are not cut or pinched If the wires appear to be intact unplug the P2 connector on the appliance manager Go to Step 7 7 Measure indicated temperature sensor resistance value measure between appropriate P2 connector pins For the following sensors the resistance value should read Main Oven Sens...

Страница 4: ...wer 7 Replace appliance manager Go to Step 11 8 Unplug oven or disconnect power 9 Check integrity of latch mechanism from cam to latch pawl and door slot Ensure that pawl aligns with the door slot Correct any mechanical malfunction 10 Check continuity of the latch motor and of electrical connections between appliance manager P8 and motor If continuity is present replace appliance manager Go to Ste...

Страница 5: ... To Enter Diagnostics Mode 1 Unplug oven or disconnect power Wait 10 seconds 2 Plug in oven or reconnect power 3 Enter into Diagnostics mode by pressing OFF OFF START 4 Press BAKE Ensure Bake relay energizes by inspecting Bake element 5 Press BROIL 1 time for outer broil element Ensure Outer Broil relay energizes by inspecting the Outer Broil element 6 Press BROIL again for Inner Broil element Ens...

Страница 6: ... F Blower speed resistor G Blower H Blower motor I Oven temperature sensor on rear panel J Control power transformer K Appliance manager L Keypad user interface board placed behind it M Door lock latch N Halogen light O In Out broil element P Oven door glass Q Door gasket R Meat Probe on some models S Hidden bake element D C E F G I J K M N O P Q R S B A H L Part Number Opening Temp Resetting Clos...

Страница 7: ...f Off On On or Off On Low speed InBroil Pre A Off On Off Off Off On On or Off On Low speed InBroil SS Off Cycling Off Off Off On On or Off On Low speed CBroil Pre B Off On On Off On On On or Off On Low speed CBroil Pre A Off On On Off On On On or Off On Low speed CBroil SS Cycling Cycling Cycling Off On On On or Off On Low speed CRoast Pre B On Cycling Cycling Off On On On or Off On Low speed CRoa...

Страница 8: ...on resettable Rear T1 2 R W to In Broil OR and Bake R Closed Circuit Bake element Rear T3 3 R to In Broil OR and Thermal Fuse 26 30Ω Inner broil element Front T3 4 OR to Bake R and Thermal Fuse 31 36Ω Outer broil element Front T3 1 BU to T2 1 R 53 59Ω Convection ring element Front T3 2 Y to T2 1 R 33 37Ω Convection fan motor Rear P8 3 OR to Neutral W 8 12Ω Latch switch Front P1 4 T to P1 5 BR Door...

Страница 9: ...1 P2 2 P2 5 P2 6 P1 5 P1 4 P8 1 P8 5 P5 1 P5 3 P9 5 P1 7 T4 4 T4 3 V OR OR OR T T BR BR BU BU W BK BK BK BK Y BR Door Switch On Latch Assy Latch Switch Operated By Motor R W G EOL Tester Connection P7 3 P7 1 T3 2 T3 3 T3 4 T3 1 T1 1 T1 2 T2 1 T2 2 P8 3 P8 6 P8 4 P9 2 R R R OR OR OR W W W GY BU BU R R W BK W R W R W Y Y GY GY Blower Speed Resistor W W W BK BK GY Conv 1600W Optional Bake 2000W In Br...

Страница 10: ...2 P8 4 Blower Speed Resistor Blower Thermal Cutoff Non Resettable 221 F 105 C BK In Broil 1800W Out Broil 1450W W R W N L2 BU OR BK BK T4 3 T4 4 P8 1 BK L1 T3 4 T3 1 OR R R R W R W BU OR GY GY T1 1 T1 2 T2 1 T2 2 P8 4 P8 3 Blower Speed Resistor Blower Thermal Cutoff Non Resettable 221 F 105 C BK In Broil 1800W Out Broil 1450W W R W W N L2 BU OR Conv Fan BK T4 3 P8 1 L1 BK BK BK T3 3 T1 1 T1 2 P8 4...

Страница 11: ...1 T2 2 P8 3 P8 4 T3 4 Bake 2000W Out Broil 1450W Conv Fan In Broil 1800WOR R L1 BK BK BK T4 4 P8 1 R Y R W OR GY GY Blower Speed Resistor Blower R R W W W N L2 Thermal Cutoff Non Resettable 221 F 105 C T2 2 P8 3 P8 4 T2 1 T3 2 Conv Ring 1600W Conv Fan Y N L1 BR BR BU OR T W BK BK BK BK BK W W Motor Latch Door Switch On Latch Assy Latch Switch Operated By Motor P1 5 P1 7 P1 4 T4 3 T4 4 P9 5 P8 1 P8...

Страница 12: ...W10220952A NOTE This sheet contains important Technical Service Data FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY W10220952A 9 08 FOR SERVICE TECHNICIAN S USE ONLY ...

Отзывы: