5-10
n
KitchenAid 2015 Microfiltration Dishwashers
DIAGNOSTICS & TROUBLESHOOTING
For Service Technician Use Only
Service Error Codes (continued)
FUNCTION
CODE
PROBLEM
CODE
CAUSES
WHAT TO CHECK
8-DRAINING
1-SLOW
DRAIN
OBSTRUCTED DRAIN HOSE OR PATH
1. UNPLUG DISHWASHER OR DISCONNECT POWER.
2. CHECK FOR BLOCKAGES FROM SUMP CHECK VALVE TO
CUSTOMER’S PLUMBING. POTENTIAL ITEMS, PLUGGED GARBAGE
DISPOSER OR PLUG NOT KNOCKED OUT, DRAIN LOOP CHECK
VALVE STUCK, AND/OR PLUGGED HOSES.
DRAIN PUMP IMPELLER FRACTURED
1. UNPLUG DISHWASHER OR DISCONNECT POWER.
2. REMOVE DRAIN PUMP AND CHECK IMPELLER (NORMALLY THERE
IS SOME UNEVEN RESISTANCE). IF IT IS STRIPPED, REPLACE
DRAIN PUMP.
2-DRAIN
MOTOR
ELECTRICAL
PROBLEM
LOOSE CONNECTION IN DRAIN MOTOR CIRCUIT
AND/OR OPEN DRAIN MOTOR WINDING.
UNPLUG DISHWASHER OR DISCONNECT POWER AND CHECK
RESISTANCES OF DRAIN MOTOR WINDING AND ALL CONNECTIONS
IN THE DRAIN CIRCUIT. FIX / REPLACE OPEN CONNECTION / PART.
DEBRIS STUCK IN DRAIN MOTOR IMPELLER.
1. UNPLUG DISHWASHER OR DISCONNECT POWER.
2. REMOVE DRAIN MOTOR AND DISLODGE DEBRIS FROM IMPELLER.
OPEN FUSE ON CONTROL TO DRAIN MOTOR.
REFER TO FUSE SERVICE AND RESISTANCE CHECK ON PAGE 6-4 IN
“TESTING” SECTION.
DRAIN MOTOR DRIVE CIRCUIT ON THE
CONTROL.
UNPLUG DISHWASHER OR DISCONNECT POWER AND REPLACE
CONTROL.
3-DRAIN
STUCK ON
DRAIN MOTOR DRIVE CIRCUIT ON THE
CONTROL.
1. UNPLUG DISHWASHER OR DISCONNECT POWER.
2. INSPECT DRAIN MOTOR AND CONNECTIONS FOR OVERHEATING/
SHORTING. IF EVIDENCE OF OVERHEATING/SHORTING EXISTS,
REPLACE.
9-DIVERTER
1-CAN’T
FIND
POSITION
CORRODED OR LOOSE CONNECTION IN
DIVERTER SENSOR / MOTOR CIRCUIT, OR OPEN/
SHORTED SENSOR/MOTOR.
1. CHECK OPERATION IN SERVICE DIAGNOSTICS CYCLE. LISTEN FOR
CAM CLICKING AS IT ROTATES OR INSPECT SHAFT WITH MIRROR
TO SEE IF ROTATING DURING DIVERTER INTERVAL. IF ROTATING,
THEN LIKELY THE SENSOR CIRCUIT.
2. UNPLUG DISHWASHER OR DISCONNECT POWER AND CHECK
CONNECTIONS IN DIVERTER SENSOR AND MOTOR CIRCUIT WITH
METER. FIX / REPLACE CONNECTIONS / PARTS.
3. INSPECT DIVERTER SENSOR FOR EVIDENCE OF WATER OR
CONTAMINANTS; IF YES, REPLACE.
MECHANICAL BINDING OF DIVERTER SHAFT /
DISC.
CHECK OPERATION OF DIVERTER MOTOR DURING DIAGNOSTICS.
INSPECT DIVERTER SHAFT WITH MIRROR IF MOTOR APPEARS TO
BE ON (HUMS, VIBRATES) BUT YOU SEE LIMITED ROTATION, THEN
REPLACE DIVERTER AND SEAL.
OPEN FUSE ON CONTROL TO DIVERTER MOTOR. REFER TO FUSE SERVICE AND RESISTANCE CHECK ON PAGE 6-4 IN
“TESTING” SECTION.
DIVERTER MOTOR DRIVE CIRCUIT ON THE
CONTROL.
UNPLUG DISHWASHER OR DISCONNECT POWER AND REPLACE
CONTROL.
2-STUCK ON
DIVERTER DRIVE CIRCUIT ON THE CONTROL.
1. UNPLUG DISHWASHER OR DISCONNECT POWER AND REPLACE
CONTROL.
2. INSPECT DIVERTER MOTOR AND CONNECTIONS FOR
OVERHEATING / SHORTING. IF EVIDENCE OF OVERHEATING /
SHORTING EXISTS, REPLACE.
3-DISC
MISSING
CONTROL DETECTED DIVERTER DISK IN SUMP IS
MISSING.
REMOVE LOWER SPRAY ARM, TURBO ZONE ASSEMBLY, REAR FEED
TUBE AND OUTLET COVER AND VERIFY THE ROUND DIVERTER DISK
IS INSTALLED.
4-LOWER
SPRAY ARM
ERROR
MECHANICAL BINDING OR BLOCKING OF SPRAY
ARM.
1. CHECK FOR AND REMOVE ANY BLOCKAGE OF LOWER SPRAY ARM
(UTENSILS, POT HANDLES).
2. RUN THE SERVICE DIAGNOSTIC CYCLE AND CHECK FOR THE LSA
OPERATION/FAULT DETECTION (NOTE 10). IF FAILURE STILL
EXISTS THEN:
- UNPLUG DISHWASHER OR DISCONNECT POWER. CHECK WIRING
CONNECTION OR DAMAGE AT CONTROLLED LOWER SPRAY ARM
SENSOR.
-
REFER TO FUSE SERVICE AND RESISTANCE CHECK ON PAGE 6-4 IN
“TESTING” SECTION. 1 (REPLACE CONTROL IF OPEN).
- CHECK FOR OPEN OR SHORTED LOWER SPRAY ARM MOTOR
WINDING RESISTANCE. REPLACE DIVERTER MODULE.
CORRODED OR LOOSE CONNECTION IN SPRAY
ARM SENSOR/MOTOR CIRCUIT.
OPEN FUSE ON CONTROL TO SPRAY ARM
MOTOR.
SPRAY ARM DRIVE CIRCUIT ON THE CONTROL.
Содержание KDTM354E
Страница 14: ...1 10 n KitchenAid 2015 Microfiltration Dishwashers GENERAL INFORMATION Notes ...
Страница 30: ...2 16 n KitchenAid 2015 Microfiltration Dishwashers OPERATION Notes ...
Страница 120: ...6 20 n KitchenAid 2015 Microfiltration Dishwashers TESTING Notes ...
Страница 122: ...W10787848A KitchenAid 2015 Microfiltration Dishwashers with Advanced ProDry ...