4. Slide the compression nut over the sleeve and screw into the
water valve inlet port.
5. Using an adjustable wrench, hold the nut on the plastic water
line to keep it from moving. Then, with a second wrench turn
the compression nut on the copper tubing counterclockwise
to completely tighten. Do not overtighten.
6. Check connection by pulling on copper tubing. Attach copper
tubing to refrigerator cabinet with a “P” clamp. Turn on water
supply to refrigerator and check for leaks. Correct any leaks.
Complete the Installation
1. Plug into a grounded 3 prong outlet.
NOTE: Allow 24 hours to produce the first batch of ice. Discard
the first three batches of ice produced. Allow 3 days to
completely fill the ice container.
Refrigerator Door(s) and Drawer
Graphics are included later in this section.
Remove and Replace Handles
1. Using a
³⁄₃₂
" Allen wrench, loosen the two set screws located
on the side of each handle. See Graphics 1 and 2.
2. Pull the handle straight out from the door. Make sure you
keep the screws for reattaching the handles.
3. To replace the handles, reverse the directions.
Remove Doors and Hinges
IMPORTANT:
■
Remove food and any adjustable door or utility bins from
doors.
■
All graphics referenced in the following instructions are
included later in this section after “Final Steps.”
TOOLS NEEDED:
⁵⁄₁₆
",
³⁄₈
",
¹⁄₄
" hex-head socket wrench,
#2 Phillips screwdriver, and a flat-blade screwdriver.
1. Unplug refrigerator or disconnect power.
2. Keep the refrigerator doors closed until you are ready to lift
them free from the cabinet.
NOTE: Provide additional support for the refrigerator door
while the hinges are being removed. Do not depend on the
door gasket magnets to hold the door in place while you are
working.
3. Starting with the right-hand side door, remove the parts for
the top hinge as shown in Top Hinge graphic. Lift the
refrigerator door from the bottom hinge pin.
NOTE: On some models, remove the shim from the bottom
hinge pin and keep it for later use. See Bottom Hinge graphic.
4. Before removing the left-hand side door, disconnect the
wiring plug located on top of the top hinge by wedging a flat-
blade screwdriver or your fingernail between the two
sections. See Wiring Plug graphic.
NOTE: The green, ground wire remains attached to the hinge.
5. Remove the parts for the top hinge as shown in Top Hinge
graphic. Lift the left-hand side door from the bottom hinge
pin.
NOTE: On some models, remove the shim from the bottom
hinge pin and keep it for later use. See Bottom Hinge graphic.
A. Plastic water tubing
B. Sleeve
C. Compression nut
D. Copper tubing
A. Plastic water line
B. Water valve inlet port
C. Compression nut
D. Copper tubing
E. “P” clamp
B
A
C
D
B
A
C
D
E
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Electrical Shock Hazard
Disconnect power before removing doors.
Failure to do so can result in death or electrical shock.