Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green
ground connector in terminal box.
Do not use an extension cord.
Failure to do so can result in death,
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green
ground connector in terminal box.
Do not use an extension cord.
Failure to do so can result in death,
fire, or electrical shock.
WARNING
7G.
Route direct wire through
conduit and connect wires as follows:
• Form ground wire into a hook and
wrap clockwise around ground
screw under washer. Tighten ground
screw securely.
green ground
connector
ground
wire
direct
wire
7H.
Reinstall terminal box.
IMPORTANT:
The tabs must be under
the terminal box as shown.
tabs
terminal
box
8.
Apply Teflon
®
tape or pipe joint
compound to 90° elbow fitting and
connect fitting to water inlet valve.
Use adjustable wrench and tighten
elbow until snug and facing the
direction needed for your water fill
line installation.
IMPORTANT:
If you are installing the
Hot Water Accessory Tank, go back to
its Installation Instructions and
complete the installation at this time.
9.
Connect the dishwasher water
fill line.
• Slide nut onto copper tubing about
1 inch (2.54 cm).
• Slide ferrule onto the tubing. Do not
position ferrule on end of tubing.
• Put tubing into fill fitting as far as it
will go.
• Slide nut and ferrule forward and
start nut onto elbow threads. Be
careful when handling and
positioning copper tubing. It bends
and kinks easily.
• With copper tubing pushed into
elbow as far as it will go, use a 5/8"
open-end wrench and tighten the
compression nut securely.
10.
Connect hot and cold water
lines to faucet.
11.
Connect the sink and
dishwasher drain plumbing.
12.
Turn water supply on to both
dishwasher and sink faucet. Check for
leaks.
13.
Plug in dishwasher or
reconnect power.
IMPORTANT:
The following steps must
be done before using the dishwasher,
to test and activate the GFCI.
14.
Press the reset button on the
GFCI. The indicator should be visible.
15.
Press the test button on the
GFCI. The indicator should disappear.
• Use twist-on connectors of proper
size to connect direct wire to
16-gauge wire dishwasher wiring.
Connect black wires together and
white wires together.
water fill line
connection
do not apply Teflon
®
tape or pipe joint
compound
apply Teflon
®
tape
or pipe joint
compound
water inlet
valve
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
Electrical Shock Hazard
WARNING
POWER SUPPLY CORD METHOD:
DIRECT WIRE METHOD:
reset
test
indicator
6