7. Maintenance and Inspection
7-1. Maintenance and inspection of the cylinder
○
If any malfunction occurs, return cylinder to our company for repair. If it is disassembled
and reassembled at a place other than our company, it may not function correctly as
well as cause precision failure.
○
If rust or mist adheres to the gap between the detectable plate and the rotary valve, the
sliding resistance will increase and the detectable plate may be damaged. Check the
gap between the detectable plate and the rotary valve for sticky substances about once
a year. If there is sticky material, clean it and remove it. Follow the procedure below for
cleaning. Please refer to (1-4. Parts list on pages 7 and 8). Removing parts, make a
matching mark on each part as a mark when reassembling.
①
Move the cylinder to the back end.
②
Remove the A to C port pipes and drain pipes.
③
Remove the Socket button head cap screw [23] (3 places), and then remove the
ring [9].
④
Remove sticky material while spraying lubricant on the gap between the inner
diameter of the detectable plate [8] and the outer diameter of the rotary valve [4].
⑤
After connecting the hydraulic port, repeat the push-pull operation of the cylinder
several times to confirm that there is no problem.
Assemble in the reverse order of disassembly.
Tighten the Socket button head cap screw with the specified tightening torque.
(M6: 8.6 N
・
m)
・
If mist adheres to the cylinder, improve the environment so that it does not adhere. If
there is a lot of adhesion, the sliding resistance of the detectable plate will increase,
and the detectable plate may be damaged.
・
If there is a lot of mist adhering and disassembly and cleaning is required, send it
back to our company for cleaning.
7-2. Maintenance and inspection of hydraulic unit
○
Clean the suction strainer every 2 to 3 months.
○
Replace the hydraulic oil about once every six months.