22
7-3. Disassembling
Disassembling procedures
Read the following disassembling procedures with reference to page 11,12.
①
Turn off the main power of the machine before starting work.
②
If the fixture and jaw are attached to the chuck, please remove in advance.
③
Please loosen the socket head cap screws
(
M10
×
40
)
[01]
while hanging at eye
bolts chuck. Then, loosen the connection with the draw pipe by turning the spindle,
remove the chuck from the spindle.
④
Loosen the
socket head cap screws
(
M4
×
12
)
[03] and remove the cover A [H].
⑤
Loosen the
set screw flat point
(
M8
×
8
)
[13] and remove the spring(yellow) [11]
and parallel pin (
φ
6×18) [12].
⑥
Loosen the set screw flat point
(
M8
×
8
)
[07] and set screw half dog point
(
M6
×
16
)
and remove the rever pin [F].
⑦
Please remove
the
socket head cap button screws
(
M6
×
12
)
[05]
.
⑧
Please remove
the master jaw [B]
and
the spring(blue) [10] and the spring(yellow)
[11] to the outer periphery side of the chuck..
⑨
Please remove
the rever [E] to the chuck front side.
⑩
Remove the plunger [G] to the chuck rear side.
⑪
Loosen the
socket head cap screws
(
M4
×
8
)
[04] and remove the cover B [J].
Assemble again while sufficiently coating the recommended grease in the reverse
procedures of disassembling. At this time, pay sufficient attention so as not to make
a mistake in the jaw numbers. Always tighten the bolts at the specified torque.
・
Use an eyebolt or a hanging belt when attaching and detaching the chuck to
and from the machine, as there is a danger of injury or damage if the chuck
drops.
Chuck size
(inch)
Eyebolt
8
M10
Содержание HG-A97-212
Страница 2: ...1...
Страница 12: ...11 Structural drawing and Parts list Structural drawing Fig 1...