1.1 Piping
Install the pipe by following
the arrow indication that
shows the air flow direction
on the product.
Blow the air to flush out the foreign matters, dust
and etc. before installing the pipe.
Uncleaned air may cause malfunction or damage
to the product.
Piping for the One-Touch Fitting, insert the tube
firmly into the fitting and make sure it cannot be
pulled out.
Also using the proper tube cutter is recommended
to ensure square edge tube.
※
Recommends using PU tube.
Flow direction
Use straight piping 8cm or longer to connect the Piping Port (Inlet side).
If straight piping is not installed, the accuracy may vary by ± 2% F.S..
※
Straight Piping: The pipe is without bending and the cross sectional areas of the
pipe keeps the same.
While installing the KF01-101/201 to the pipe, please apply air tube with
I.D. 5 mm.
While installing the KF01-005/010/050/100/500 to the pipe, please apply air
tube with I.D. 4 mm.
※
The accuracy can vary by
approximately ±2% F.S.
when such tubing is not
used.
Piping Port
(Inlet side)
straight piping 8cm
or longer
Piping Port
(Outlet side)
1.1.1 Piping for the One-Touch Fitting