Trouble. When there is a lot of Pre-processing image error
Solution 1. Remove dust on the CIS.
Solution 2. Check the GAP of insert module using Test-Note
Solution 3. Adjust the GAP for insert module. (- direction or + direction ,
P1.1 See picture below)
Solution 4. Check the skew using Test-Note. & newton APL
Solution 5. Update the currency SW again using USB.
Trouble. When there is a lot of denomination recognizing error(Reference F1.2)
Solution 1. Remove dust on the CIS.
Solution 2. Check the image using Test-Note.
Solution 3. If the image is abnormal, Try CIS calibration
Solution 4. Update the currency SW again using USB.
Simple Trouble shooting guide1