4. UNIT 

OPERATION 

WARNING:

 RISK OF EQUIPMENT DAMAGE 

 

  For MW 1210, MW 1215: Do not plug surge-protected power bars into the unit’s 120 VAC 

outlets. The surge protected components on the surge-protected power bar may not like the 
modified sine wave output generate by the inverter. 

  Do not connect an AC power source like utility power or generator to the unit 120 VAC outlets.  

 

Turn ON and OFF the 120 VAC and USB 

 

Press and hold the “Power/Select” button for 1 second until a beep is sounded. Display will 
show the measured battery voltage and output power alternatively. Status LED will turn 
green. Both 5V USB and 120 VAC are available. 

 

Press “Power/Select” button to turn unit off. 

 

Remote ON /OFF (Optional) 

 

If optional remote is used, the Remote ON/OFF momentary switch is connected in parallel 
with the “Power/Select” button on the unit. Same procedure applies to ON and OFF the unit.

 

  

Understanding the Display & Status LED 

  

Display: 

 

   ’12.5’ 

Display shows measured battery voltage 

 

   ‘0.80’   Display shows total output AC power in kW (800W as shown) 

 

   ‘E01’ 

Display shows error or warning code. See trouble shooting section in details 

 

 Status LED: 
   Green:  Unit operation is normal 

 

   Amber:  Warning is detected. Unit will shutdown at any time. Please check error code to  

troubleshoot the unit. 

 

   Red: 

Error is detected and unit has shutdown. Please check error code to troubleshoot  
the unit. 

  

Understanding the Error Code 

Code Condition 

Corrective 

Action 

E01 

Unit has sensed input under voltage 
and has shutdown 

Recharge battery immediately and 
restart unit 

E02 

Unit has sensed input over voltage 
and has shutdown 

Check battery voltage or if any external 
charger is connected to the battery bank 

E03 

Unit output has sensed overload or 
short circuit and was shutdown 

Check load connected to the output. 
Reduce load and restart the unit 

E04 

Unit has sensed internal 
temperature was high and has 
shutdown 

Turn unit off and wait for 15 minutes 
before restarting. Check if any object 
has blocked the air flow of the unit 

E05 

Unit has sensed input voltage is low 
and warning occurs 

Recharge battery as unit will shutdown 
shortly 

E06 

Unit has sensed load connected is 
close to overload shutdown limit 
(Not applicable for MW1210, 
MW1215) 

Reduce load 

E07 

Unit has sensed internal 
temperature is high and is close to 
thermal shutdown limit 

Reduce load and check if any ventilation 
of the unit is blocked 

 

AC Load on Power Inverter 

Although the Power Inverter can provide high surge power up to two times the rated output power, 
some appliances may still trigger on the inverter protection system. A higher power inverter is 
required for those appliances. 
For MW 1210, 1215 modified sinewave inverter, some appliances like speed controllers found in 
some fans, power tools and some power tools’ AC charger may not like the modified sine wave 

Содержание MW 1210

Страница 1: ...Modified Sinewave Power Inverter 1000 1500 MW 1210 MW1215 True Sinewave Power Inverter 1000 2000 SW 1210 SW 1220 Owner s Manual Modified Sinewave Series True Sinewave Series ...

Страница 2: ...cations and product functionality may change without notice Important Please be sure to read and save the entire manual before using your KISAE Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers Modified Sinewave series MW 1210 Power Inverter 12V 1000W MW 1...

Страница 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 9 5 TROUBLESHOOTING 10 6 SPECIFICATIONS 11 7 WARRANTY 12 ...

Страница 4: ...follow all the battery manufacturer s specific precautions when installing using and servicing the battery connected to the inverter Wear eye protection and gloves Avoid touching your eyes while using this unit Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical att...

Страница 5: ...UCT DESCRIPTION The KISAE Power Inverter package includes the items list below Power Inverter base unit one of the following models MW 1210 Power Inverter 1000 Modified Sinewave MW 1215 Power Inverter 1500 Modified Sinewave SW 1210 Power Inverter 1000 True Sinewave SW 1220 Power Inverter 2000 True Sinewave Owner s manual P N MU MW1215 3 INSTALLATION WARNING KISAE Technology recommends that all wir...

Страница 6: ...urer The fuse or circuit breaker chosen has to be able to withstand the short circuit current that may be generated by the battery bank Disconnect Switch Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit breaker from the above The Disconnect Switch is used to disconnect the DC power between the power inverter and the battery bank during service maintenan...

Страница 7: ... For indoor use the orientation of the unit can be mounted in any direction except with the DC Input panel facing downwards For RV installation the unit has to be mounted flat on horizontal surface Use mounting template below to mark the positions of the mounting screws Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting surface Power Inverter Chas...

Страница 8: ...lder Turn Disconnect Switch to ON position Remote Switch optional Connection Insert the Remote Switch to the RJ11 Remote Port located at the Front AC panel of the Power inverter Please note polarity Test the Power Inverter connection Turn unit on by pressing and holding the On Off button on the main unit for about a second until a beep sound occur The Status light turns on indicating the KISAE Pow...

Страница 9: ... shutdown Please check error code to troubleshoot the unit Understanding the Error Code Code Condition Corrective Action E01 Unit has sensed input under voltage and has shutdown Recharge battery immediately and restart unit E02 Unit has sensed input over voltage and has shutdown Check battery voltage or if any external charger is connected to the battery bank E03 Unit output has sensed overload or...

Страница 10: ...OOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Error Codes in section 4 Problem Symptom Solution No output voltage And Status LED is off The unit is off Turn unit ON by following the instruction in Section 4 to turn unit ON No power to inverter Check fuse or the Disconnect switch if installed is either blown or turn OFF No AC o...

Страница 11: ... 5 VDC Under Voltage Recovery 11 8 VDC Over Voltage Shutdown 15 5 VDC USB 5V 750 mA Safety and Environmental Conformance Conforms to UL 458 Certified to CSA C22 2 no 107 1 Agency Markings cETLus Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Relative Humidity 5 90 noncondensing Operating Altitude Up to 9 843ft 3000 meters above sea level Weights and D...

Страница 12: ...tail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year from ...

Отзывы: