Connect the other side of the cable to the common grounding point. 

 
Power Inverter DC Input Connection: 

CAUTION

: Reverse the DC Input terminal will damage the unit and cannot be repaired. 

Damage caused by reverse polarity connection is not covered by the warranty.  

 

Connect one end of the negative DC input cable to the Power Inverter DC negative terminal. 
Connect the other end of the negative DC input cable to the battery negative terminal. 

 

Make sure the Disconnect Switch is in the OFF position. 

 

Connect one end of the positive DC input cable to the Power Inverter DC positive terminal. 
Connect the other end of the positive DC input cable to one of the terminal of the Disconnect 
Switch. 

 

Connect a DC input cable between the other terminal of the Disconnect Switch and one side 
of the terminal of the fuse holder. 

 

Connect a DC input cable between the other terminal of the fuse holder and the battery 
positive terminal. 

 

Install the selected fuse to the fuse holder. 

 

Turn Disconnect Switch to ON position. 
  

Remote Switch (optional) Connection: 

 

Insert the Remote Switch to the RJ11 Remote Port located at the Front AC panel of the 
Power inverter. Please note polarity. 

 

Test the Power Inverter connection: 

 

Turn unit on by pressing and holding the On/Off button on the main unit for about a second 
until a beep sound occur. The ‘Status’ light turns on indicating the KISAE Power Inverter is 
ON. Check the digital display show measured battery voltage and output power alternatively. 
Both AC output and 5V USB are now available.  

 

Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify 
AC is available. If AC is not available, the GFCI may be tripped. Reset the GFCI by pressing 
the ‘RESET’ button. 

 

The unit is successfully installed and functioning properly. 

 
Test the GFCI monthly: 

 

Use the following instruction to perform a monthly test on the GFCI to ensure the GFCI is 
functioning properly. 

 

Turn unit on and plug a small AC load (40W light bulbs) to the GFCI.  

 

Check the AC load is ON. 

 

Press ‘Test’ button and observe a click sound. Check AC load is turned off. 

 

Press ‘RESET’ button and check the AC load is back ON again.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MW 1210

Страница 1: ...Modified Sinewave Power Inverter 1000 1500 MW 1210 MW1215 True Sinewave Power Inverter 1000 2000 SW 1210 SW 1220 Owner s Manual Modified Sinewave Series True Sinewave Series ...

Страница 2: ...cations and product functionality may change without notice Important Please be sure to read and save the entire manual before using your KISAE Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers Modified Sinewave series MW 1210 Power Inverter 12V 1000W MW 1...

Страница 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 9 5 TROUBLESHOOTING 10 6 SPECIFICATIONS 11 7 WARRANTY 12 ...

Страница 4: ...follow all the battery manufacturer s specific precautions when installing using and servicing the battery connected to the inverter Wear eye protection and gloves Avoid touching your eyes while using this unit Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical att...

Страница 5: ...UCT DESCRIPTION The KISAE Power Inverter package includes the items list below Power Inverter base unit one of the following models MW 1210 Power Inverter 1000 Modified Sinewave MW 1215 Power Inverter 1500 Modified Sinewave SW 1210 Power Inverter 1000 True Sinewave SW 1220 Power Inverter 2000 True Sinewave Owner s manual P N MU MW1215 3 INSTALLATION WARNING KISAE Technology recommends that all wir...

Страница 6: ...urer The fuse or circuit breaker chosen has to be able to withstand the short circuit current that may be generated by the battery bank Disconnect Switch Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit breaker from the above The Disconnect Switch is used to disconnect the DC power between the power inverter and the battery bank during service maintenan...

Страница 7: ... For indoor use the orientation of the unit can be mounted in any direction except with the DC Input panel facing downwards For RV installation the unit has to be mounted flat on horizontal surface Use mounting template below to mark the positions of the mounting screws Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting surface Power Inverter Chas...

Страница 8: ...lder Turn Disconnect Switch to ON position Remote Switch optional Connection Insert the Remote Switch to the RJ11 Remote Port located at the Front AC panel of the Power inverter Please note polarity Test the Power Inverter connection Turn unit on by pressing and holding the On Off button on the main unit for about a second until a beep sound occur The Status light turns on indicating the KISAE Pow...

Страница 9: ... shutdown Please check error code to troubleshoot the unit Understanding the Error Code Code Condition Corrective Action E01 Unit has sensed input under voltage and has shutdown Recharge battery immediately and restart unit E02 Unit has sensed input over voltage and has shutdown Check battery voltage or if any external charger is connected to the battery bank E03 Unit output has sensed overload or...

Страница 10: ...OOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Error Codes in section 4 Problem Symptom Solution No output voltage And Status LED is off The unit is off Turn unit ON by following the instruction in Section 4 to turn unit ON No power to inverter Check fuse or the Disconnect switch if installed is either blown or turn OFF No AC o...

Страница 11: ... 5 VDC Under Voltage Recovery 11 8 VDC Over Voltage Shutdown 15 5 VDC USB 5V 750 mA Safety and Environmental Conformance Conforms to UL 458 Certified to CSA C22 2 no 107 1 Agency Markings cETLus Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Relative Humidity 5 90 noncondensing Operating Altitude Up to 9 843ft 3000 meters above sea level Weights and D...

Страница 12: ...tail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year from ...

Отзывы: