3.

 

COMMISSIONING/START-UP/OPERATION:

 

 

3.1

 

Preparations –

 

 
Fill the pump with the liquid to be pumped and vent it by means of the vent nipples 
on  the  flanges.  Pumps  in  mechanical  seal  construction  must  be  vented  too,  by 
means  of  screwed  plugs,  provided  on  the  mechanical  seal  cover.  Venting  is  also 
necessary in case of positive suction and for hot liquids. 
 
Pump  is  to  be  filled  only  once  and  may  be  filled  prior  to  connecting  the  piping  to 
suction  and  delivery  flanges.    For  all  subsequent  start-ups  the  pump  will  operate 
with self-priming.   

 

Check that the shaft rotates freely.   Check that all auxiliary connections are ready 
for operation. 
 
Open all shutoff valves in suction and discharge lines! 
 
Never start up the pump with the discharge side closed! If the unit is fitted with a 
bypass line, see that it is closed for suction lift  operation; with positive suction it 
may remain open. 
 
As  the  bearings  are  permanently  packed  with  grease,  no  further  greasing  is 
required. Bearings used are self-lubricated.   

 
3.2

 

Motor – 

 

 
Check the operating voltage and speed of the motor. 
 
The speed of the 50 Hz model is 1450 rpm. The speed of the 60 Hz model is 1750 
rpm. 
 
Provide a motor tripping device! 
 
Check the direction of rotation of the motor with respect to pump by switching the 
motor on and then off again immediately. The direction of rotation of the pump is 
indicated on the pump by direction arrow nameplate. 
 
Never run the pump in reverse direction of rotation! 
 
The  electrical  connections  are  to  be  made  by  an  authorized  electrician  and  in 
compliance local regulations, in  particular in respect  of the safety measures to be 
performed. 
 

Содержание CF 110 Series

Страница 1: ...KIRLOSKAR BROTHERS LIMITED KIRLOSKARVADI 416 308 INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE CF...

Страница 2: ...ipment or 18 months from the date of despatch from our factory whichever is earlier Our liability in respect of any complaint is limited to replacing part parts free of charge ex works or repairs of t...

Страница 3: ...KIRLOSKAR BROTHERS LIMITED KIRLOSKARVADI 416 308 CONTENTS 1 GENERAL 2 INSTALLATION 3 OPERATION 4 TECHNICAL DATA 5 MAINTENANCE 6 OVERHAULING 7 SPARE PARTS LIST AND CROSS SECTIONAL DRAWING...

Страница 4: ...it should be indicated and located in a dry place The coupling should be rotated once in a month to prevent pitting of bearing surfaces 1 4 Each pump is subjected to a functional test prior to shipmen...

Страница 5: ...liquids containing solids with a grain size larger than 60 microns in some cases a filter can be fitted on the suction side The pump must be supplied with liquid at all times it must never run dry The...

Страница 6: ...cidents it is necessary to use coupling guard 2 2 Piping Before connecting the piping remove the anticorrosive agent filled into the pump before shipment this only applies to pumps made from gray cast...

Страница 7: ...vitation which in turn could destroy the hydraulic parts The decisive factors for determining the NPSH available value are temperature vapour pressure density suction head and pipe loss 2 4 Valves Fit...

Страница 8: ...lines Never start up the pump with the discharge side closed If the unit is fitted with a bypass line see that it is closed for suction lift operation with positive suction it may remain open As the b...

Страница 9: ...3 4 1 General Never run the pump without liquid or with a prolonged interruption of the flow Pump and motor should run smoothly quietly and free from vibrations at all times All shut off valves filter...

Страница 10: ...cooling liquid enters the housing in the upper section of the pump foot whereas it drains off diagonally across on the opposite side see Fig 3 3 4 6 Sealing liquid connection for pump with stuffing bo...

Страница 11: ...river The shutoff valves need not be closed if non return valves are fitted The shutoff valve on the suction side is to be closed both during prolonged standstill of the pump and if there is an overpr...

Отзывы: