KIRLOSKAR CF 110 Series Скачать руководство пользователя страница 3

KIRLOSKAR BROTHERS LIMITED 
KIRLOSKARVADI  416 308 
 

 
 

CONTENTS 

 
 
 
 
 
 

1.

 

GENERAL. 

 
 
2.

 

INSTALLATION. 

 
 
3.

 

OPERATION. 

 
 
4.

 

TECHNICAL DATA. 

 
 
5.

 

MAINTENANCE. 

 
 
6.

 

OVERHAULING. 

 
 
7.

 

SPARE PARTS LIST AND  
CROSS SECTIONAL DRAWING. 

 
 
 
 
 
 
 

Содержание CF 110 Series

Страница 1: ...KIRLOSKAR BROTHERS LIMITED KIRLOSKARVADI 416 308 INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE CF...

Страница 2: ...ipment or 18 months from the date of despatch from our factory whichever is earlier Our liability in respect of any complaint is limited to replacing part parts free of charge ex works or repairs of t...

Страница 3: ...KIRLOSKAR BROTHERS LIMITED KIRLOSKARVADI 416 308 CONTENTS 1 GENERAL 2 INSTALLATION 3 OPERATION 4 TECHNICAL DATA 5 MAINTENANCE 6 OVERHAULING 7 SPARE PARTS LIST AND CROSS SECTIONAL DRAWING...

Страница 4: ...it should be indicated and located in a dry place The coupling should be rotated once in a month to prevent pitting of bearing surfaces 1 4 Each pump is subjected to a functional test prior to shipmen...

Страница 5: ...liquids containing solids with a grain size larger than 60 microns in some cases a filter can be fitted on the suction side The pump must be supplied with liquid at all times it must never run dry The...

Страница 6: ...cidents it is necessary to use coupling guard 2 2 Piping Before connecting the piping remove the anticorrosive agent filled into the pump before shipment this only applies to pumps made from gray cast...

Страница 7: ...vitation which in turn could destroy the hydraulic parts The decisive factors for determining the NPSH available value are temperature vapour pressure density suction head and pipe loss 2 4 Valves Fit...

Страница 8: ...lines Never start up the pump with the discharge side closed If the unit is fitted with a bypass line see that it is closed for suction lift operation with positive suction it may remain open As the b...

Страница 9: ...3 4 1 General Never run the pump without liquid or with a prolonged interruption of the flow Pump and motor should run smoothly quietly and free from vibrations at all times All shut off valves filter...

Страница 10: ...cooling liquid enters the housing in the upper section of the pump foot whereas it drains off diagonally across on the opposite side see Fig 3 3 4 6 Sealing liquid connection for pump with stuffing bo...

Страница 11: ...river The shutoff valves need not be closed if non return valves are fitted The shutoff valve on the suction side is to be closed both during prolonged standstill of the pump and if there is an overpr...

Отзывы: