background image

GAS-FIRED INFRARED   

OUTDOOR PATIO HEATER   

                                                                           

INSTALLATION, OPERATION

         

MAINTENANCE INSTRUCTIONS 

 

 

 
 
 
 
 
 

FOR MODEL PTH106A-SS 

 

TABLE OF CONTENTS

                                                                                                     

PAGE 

IMPORTANT …………………………………………………………………… 

 

  1 

TOOLS & PARTS ……………………………………………………………….. 

 

  2   

PRECAUTIONS…………………………………………………………………..   

 3     

ASSEMBLY INSTRUCTIONS …………………………………………………. 

 

  4     

GAS REQUIREMENTS & LEAK TESTING ………………………………….. 

 

  7   

SAFETY CHECKS ……………………………………………………………….   

  8 

LOCATING HEATER FOR USE ………………………………………………. 

 

  9 

LIGHTING / SHUTDOWN ……………………………………………………….       10 
STORAGE / BURNER REMOVAL………………………………..…………….   

  12 

BURNER INSTALLATION / PILOT CLEANING ………………………………            13 
BURNER REMOVAL …………………………………………………………….   

 14  

TROUBLE SHOOTING .…………………………………………………………   

  15 

PARTS LIST ………………………………………………………………………       16 
WARRANTY ………………………………………………………………………       17 

 

READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND BE SURE YOUR PATIO HEATER IS 
PROPERLY INSTALLED, ASSEMBLIED AND CARED FOR. FAILURE TO FOLLOW THESE 
INSTRUCTIONS MAY RESULT IN SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. IF 
YOU HAVE QUESTIONS CONCERNING ASSEMBLY OR OPERATION, CONSULT YOUR 
DEALER, GAS APPLIANCE SERVICE REPRESENTATIVE OR YOUR GAS COMPANY. 

 

NOTE TO INSTALLER:   
LEAVE THESE INSTRUCTIONS WITH THE CONSUMER AFTER INSTALLATION.   

 

NOTE TO THE CONSUMER:   
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.   

 

 

STOP 

PLEASE CONTACT 1-800-913-8999 FOR ASSISTANCE   
DO NOT RETURN TO PLACE OF PURCHASE

 

 

Содержание PTH106A-SS

Страница 1: ...LIST 16 WARRANTY 17 READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND BE SURE YOUR PATIO HEATER IS PROPERLY INSTALLED ASSEMBLIED AND CARED FOR FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS BO...

Страница 2: ...n cause severe property damage or serious injury or death Please read the installation operation maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY If yo...

Страница 3: ...ank Enclosure Assembly 1 LPG Gas regulator with Hose 1 Hardware Bag Page2 Post Socket 1 4 Acorn cap 4 Post Socket 1 4 Flat Washer 4 Reflector 5 32 Truss Head Screw 3 Reflector Plate 1 4 Truss Head Scr...

Страница 4: ...amage the heater and render it unsafe for use Check the heater immediately if any of the following exists 1 The smell of gas in conjunction with extreme yellow tipping of the burner flames 2 The heate...

Страница 5: ...TIONS Page4 STEP 1 Attach Table Legs z Attach the post socket to the top of the tank enclosure using four 1 4 M6 flat washers and four 1 4 M6 acorn caps z Secure the four table legs with four of 5 32...

Страница 6: ...or then tighten up with three 1 4 M6 truss head screws from the bottom up STEP 2 STEP 3 Attach The Reflector nut Post z Screw the 1 4 x 2 3 4 M6x60mm dual threaded end stud into the emitter top z Atta...

Страница 7: ...to the bracket of tank enclosure as show in diagram STEP 5 Attach Regulator Attach flare adapter on hose end of the regulator assembly to the flare fitting on the intake hose Secure the other end of r...

Страница 8: ...n must conform with local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 1996 z The heater comes equipped with a hose assembly for hook up to a standard z A dented rust...

Страница 9: ...h See diagram for Step 1 NOTE The remaining connections are to be tested after the heater has been lit STEP 2 4 Light the heater following instructions on page 10 and page 11 6 8 7 9 STEP 2 5 Using sp...

Страница 10: ...be maintained at all times The installation must conform to local codes or in the absence of local codes with the standard for the storage and handling of liquid petroleum gases In the US use ANSI NFP...

Страница 11: ...r clockwise direction Check for leaks by applying soapy water to the tank and hose connections D Push and turn the gas control knob to PILOT position The igniter will spark at the same time Firmly pre...

Страница 12: ...reflector the heater should be turned off immediately and the heater should not be operated again until repairs are made FIGURE 2 NORMAL FLAME POSITION 2 50 8mm 1 25 4mm 0 0mm RELIGHTING A Turn the co...

Страница 13: ...se assembly Never paint the reflector emitter assembly the safety control valve cylinder valve panel or instruction plate on post The posts of the burner must remain clean so that the gas flow is unre...

Страница 14: ...etc the pilot flame may be small and the thermocouple may not heat up enough for the main burner to come on If this occurs it will be necessary to clean the pilot Lower Cone Cylinder Safety Valve Cyli...

Страница 15: ...t assembly to the lower screen cone 3 Hold the pilot assembly with slip joint pliers loosen and remove the nut at the base of the pilot 4 Inspect the pilot and tubing for blockage you should be able t...

Страница 16: ...ontrol or damaged Pilot flame not touching the thermocouple Low gas pressure Blockage in burner orifice Control knob not in ON position Purge gas line and repeat ignition operation Check gas pressure...

Страница 17: ...Main Burner Assembly Emitter base Pilot Assembly Control Housing Front Panel Lighting Instruction Plate Logo Plate Control Knob Control Housing Gas Valve Control Husing Base Post Square Table Post Soc...

Страница 18: ...use contrary to operating instructions or alteration by any person other than our factory service center The warranty period is not extended by such repair or replacement Warranty claim procedure If y...